User`s manual

RE 30126-01-B/08.07 | Manual Hydraulics | Bosch Rexroth AG 13/76
Overview of the 4WRE 6 and 4WRE 10 Valve control 2
Connecting the valve position transducer
Connection for the valve position transducer is shown in the following illustration.
VPCD_0
3
4 2
1
Valve position feedback connection
z12
z14
z16
z18
z
1
0
Fig. 3 Connecting the valve transducer
The transducer is connected using a 4-pole cable connector Pg7-G5W1F, which can
be ordered separately under material number R900023126.
Cable 4 x 0.25 mm² of type LiYCY-CY ( 4 x 30 AWG Double shielded cable) is
recommended for lengths up to 50 m.
The shield should be connected to z10 on the edge connector of the controller on the
supply side only.