16
Connecting the heat pump to the heating system
Individual temperature control in each room and increasing volume of
internal water
This solution is used to control the temperature of each room, for example, where thermostatic valves are used on the
radiators in each room. The function of the heat pump is to maintain a temperature in accordance with the heat curve
(depending on outdoor temperature) in the 100 litre primary water storage tank. The water is then distributed from the
store to the heating system. This solution also allows the overall volume of the installation to be increased if the volume of
the heating system is inadequate, for example with one or two fan-assisted radiators.
This system design is intended to ensure that the heat pump is able to continue operating if the fl ow falls below 70% of the
nominal system fl ow.
*
* Mixed heating system
There is a possibility to control a second
heating system with a mixing valve. This
is recommended when a combination of
radiators and a fl oor heating system is
used.
C11: Expansion vessel
C21: Primary storage tank
E22 : Water heater with electric heater
E42: Hot water cylinder
F21: Safety valve
G1 (P1): Radiator pump
G2 (P2): Heating system pump
G4 (P4): Pump for mixed heating system
Q41: Mixing valve
V21: Filter heating system
V40: Hot water draw-off
W40: Cold water cylinder inlet