Install Instructions

Table Of Contents
Inspection and maintenance | 71
6 720 806 992 (2013/09)Greenstar
15.1.5 Burner servicing
Remove burner lid (steps 1 - 4).
Fig. 91 Removing the burner cover
Remove burner and clean its components.
Fig. 92 Burner
Reinstall burner in reverse order, including a new gasket if necessary.
Adjust the gas-air ratio ( page 66).
15.1.6 Heat exchanger block inspection and cleaning
Remove the inspection cover ( page 10) and any sheet metal insert
below, if installed.
Determine degree of soiling of the heat exchanger through visual
inspection.
If mechanical cleaning is required:
For cleaning the heat exchanger, use Bosch main heat exchanger
gaskets, the heat exchanger brush and the heat exchanger cleaning
blade which are available as spare parts.
Remove the condensate trap (steps 1 and 2) and place a suitable
container underneath.
Fig. 93 Removing the condensate trap
DANGER: Fire danger!
Only operate the burner while installed in a boiler.
1
2
4
6 720 641 933-95.1o
3
7 181 465 330-08.2R
NOTICE: Damage to the coating of the heat exchanger.
Cleaning of the heat exchanger should not be
necessary until five years after the initial
commissioning.
Only use a Bosch cleaning blade and Bosch cleaning
brush ( page 98).
Only clean heat exchanger in case if soiling is clearly
visible.
6 720 641 933-93.1o
1
2