20 | Information about the appliance
Greenstar6 720 806 992 (2013/09)
3.13 Technical data heating boiler ZBR28-3A...
Input/Output Unit NG LPG (propane)
Max. input rate 180/79 °F (82/26 °C) BTU/hr (kW) 100,800 (29.5) 98,600 (28.9)
Max. output rate 104/86 °F (40/30 °C) BTU/hr (kW) 93,800 (27.5) 93,800 (27.5)
Max. output rate 122/86 °F (50/30 °C) BTU/hr (kW) 93,100 (27.3) 93,100 (27.3)
Max. output rate 176/140 °F (80/60 °C) BTU/hr (kW) 89,400 (26.2) 89,400 (26.2)
Min. input rate 180/79 °F (82/26 °C) BTU/hr (kW) 24,600 (7.2) 40,100 (11.7)
Min. output rate 104/86 °F (40/30 °C) BTU/hr (kW) 23,900 (7.0) 39,900 (11.7)
Min. output rate 122/86 °F (50/30 °C) BTU/hr (kW) 23,900 (7.0) 39,600 (11.6)
Min. output rate 176/140 °F (80/60 °C) BTU/hr (kW) 21,800 (6.4) 36,200 (10.6)
Gas connection value
Natural Gas – H
s
= 1,010 BTU/ft
3
(37.3MJ/m
3
)ft
3
/hr (m
3
/h) 99 (2.8)
Liquid Propane Gas – HD-S = 2,500 BTU/ft3 (93.1MJ/m3) ft
3
/hr (m
3
/h) 39 (1.1)
Permissible inlet gas pressure
NG in. W.C. (mbar) 3.5-10.5" (8.7-26.1) -
LPG (propane) in. W.C. (mbar) 8-13" (19.9-32.3)
Flue gas
Flue gas mass flow at maximum/minimum nominal output gps 12.0/3.2 11.6/4.8
Flue gas temperature 176/140 °F (80/60 °C) at maximum/minimum nominal
heat input
°F ( °C)
147/133 (64/56) 147/133 (64/56)
Flue gas temperature 104/86 °F (40/30 °C) at maximum/minimum nominal
heat input
°F ( °C)
117/90 (47/32) 117/90 (47/32)
CO
2
at max. nominal output % 9.4 11.0
CO
2
at minimum nominal output % 8.6 10.4
Condensate
Max. condensate quantity (t
R
= 86 °F (30 °C)) gph (l/h) 0.6 (2.3) 0.6 (2.3)
pH level, approx. 4.8 4.8
General
Voltage VAC 120 120
Frequency Hz 60 60
Max. power consumption (central heating mode) W 205 205
Max. power consumption (Stand-by) W < 6 < 6
Sound pressure level
dB(A)
39 39
Max. supply temperature °F ( °C) 190 (88) 190 (88)
Max. permissible operating pressure (P
MS
) heating psi (bar) 30 (2.07) 30 (2.07)
Permissible ambient temperature °F ( °C) 32 - 122 (0 - 50) 32 - 122 (0 - 50)
Nominal water capacity (heating) Gal (L) 0.925 (3.5) 0.925 (3.5)
Weight (without packaging) lbs. (kg) 103.6 (47) 103.6 (47)
Dimensions, W x H x D
inch
(mm)
17-21/64" × 33-15/32" × 13-57/64"
(440 × 850 × 353)
Table 5 Technical data heating boiler ZBR28-3A...