Install Instructions

Table Of Contents
44 | Installation
Greenstar6 720 806 992 (2013/09)
Fig. 39 Vertical venting system (sealed combustion)
[1] Intake
[2] Exhaust
X Greater than 12 inches (305 mm)
Y 12 inches (305 mm) above maximum snow level or at least
24 inches (610 mm) whichever is greater
Fig. 40 Horizontal venting system (telescopic concentric vent kit)
6.8.3 Vent and combustion air pipe lengths
3" (76 mm) Vent and combustion air pipe
For all installation situations and for all appliances the maximum vent
and combustion air pipe length is 100 feet each, with no more than
8 elbows each.
2" (50 mm) Vent and combustion air pipe
The maximum combined vent and combustion air pipe length
( tab. 20, 21 and 22) depend on the installation situation, the
appliance type and the number of elbows used.
2
6 720 641 933-08.1O
Y
X
1
Y
X
X
1/4" per foot
(50 mm per meter)
6 720 641 933
-
78.1O
Installations Fig. 32, 33, 34, 36, 37 and 39
Separate terminations
2" PIPE Maximum straight vent pipe length allowed for
Ø 2" pipe
Number of 90 °
elbows used
ZBR16-3A
ZBR21-3A
ZBR28-3A
ZWB28-3A
ZBR35-3A
ZWB35-3A
ZBR42-3A
ZWB42-3A
1 81 ft (24.6 m) 65 ft (19.8 m)
2 76 ft (23.1 m) 57 ft (17.3 m)
3 71 ft (21.6 m) 48 ft (14.6 m)
4 66 ft (20.1 m) 40 ft (12.2 m)
5 61 ft (18.6 m) 32 ft (9.8 m)
6 56 ft (17.1 m) 23 ft (7.0 m)
Table 20 Vent and combustion air pipe lengths with 2" diameter and
separate terminations
Installations Fig. 35 Stainless steel wall termination
2" PIPE Maximum straight vent pipe length allowed for
Ø 2" pipe
Number of 90 °
elbows used
ZBR16-3A
ZBR21-3A
ZBR28-3A
ZWB28-3A
ZBR35-3A
ZWB35-3A
ZBR42-3A
ZWB42-3A
1 76 ft (23.1 m) 60 ft (18.3 m)
2 71 ft (21.6 m) 52 ft (15.9 m)
3 66 ft (20.1 m) 43 ft (13.1 m)
4 61 ft (18.6 m) 35 ft (10.7 m)
5 56 ft (17.1 m) 27 ft (8.2 m)
6 51 ft (15.6 m) 18 ft (5.5 m)
Table 21 Vent and combustion air pipe lengths with 2" diameter and the
stainless steel wall termination
Installations Fig. 38 Concentric termination
2" PIPE Maximum straight vent pipe length allowed for
Ø 2" pipe
Number of 90 °
elbows used
ZBR16-3A
ZBR21-3A
ZBR28-3A
ZWB28-3A
ZBR35-3A
ZWB35-3A
ZBR42-3A
ZWB42-3A
1 66 ft (20.1 m) 47 ft (14.3 m)
2 61 ft (18.6 m) 38 ft (11.6 m)
3 56 ft (17.1 m) 30 ft (9.1 m)
4 51 ft (15.6 m) 22 ft (6.7 m)
5 46 ft (14.1 m) 13 ft (4.0 m)
6 41 ft (12.5 m) 5 ft (1.5 m)
Table 22 Vent and combustion air pipe lengths with 2" diameter and the
concentric termination