Installation manual
Note: Dimensions are for planning only. For details, see installation manual, or visit www.bosch-home.com/us. SpeciÀcations subject to change without notice.
For immediate installation dimensions by fax, call 1.925.284.3558. Use code #8317 for a directory of Bosch products. Also available online at dexpress.com.
15¾"
29⅞"
15⅜"
16½"
Oven, Microwave and Warming Drawer
Dimensions and Installation
Ovens
Built-in Microwaves
24"
28½"
23⅞"
29¾"
49½"
50"
min. 4¾"
Floorline
22"
24"
28½"
23⅞"
29¾"
51⅛"
51¾"
min. 4¾"
Floorline
22"
24"
28½"
23⅞"
29¾"
28¼"
29¹⁄₁₆"
min. 4¾"
Floorline
22"
3"
24"
25½"
23⅞"
26¾"
51⅛"
51¾"
min. 4¾"
Floorline
22"
3"
25½"
23⅞"
26¾"
28¼"
29¹⁄₁₆"
min. 4¾"
Floorline
22"
24"
Over-the-Range Microwaves
Warming Drawers
Possible area for
wall receptacle
min. 1"
opening
above
27⅜"
9⅞"
29¾"
11¼"
22"
24¹¹⁄₁₆"
includes
handle
10"
28½"
24"
10⅞"
24"
½" min.
28⅜"
22¼"
20½"
29¾"
11¼"
10⅞"
24"
½" min.
25⅜"
22¼"
20½"
26¾"
11¼"
Top of
microwave
shelf
Microwave
Cutout
Outlet should be in
the shaded area
min.
36¹⁄₁₆"
4"
21"
5½"
19⅞"
19⁵⁄₁₆"
14¹³⁄₁₆"
23⅞"
20½"
1½"
25⁷⁄₁₆" for 27" Trim Kit
28⁷⁄₁₆" for 30" Trim Kit
26¾" for
27" Trim Kit
29¾" for
30" Trim Kit
6½" for 27" Trim Kit
8" for 30" Trim Kit
min. ¾"
if oven
is below
Top of
microwave
shelf
Microwave
Cutout
Outlet should be in
the shaded area
min.
36¹⁄₁₆"
4"
21"
5½"
19⅞"
19⁷⁄₁₆"
14"
23⅞"
20½"
1½"
25⁷⁄₁₆" for 27" Trim Kit
28⁷⁄₁₆" for 30" Trim Kit
26¾" for
27" Trim Kit
29¾" for
30" Trim Kit
6½" for 27" Trim Kit
8" for 30" Trim Kit
min. ¾"
if oven
is below
12"–12⅞"
min.
66"
to floor
Grounded Outlet
(inside upper cabinet)
min. 30" clearance
from bottom of cabinet
to cooking surface of
countertop
min. 30"
cabinet
opening
width
HMV30x1U, HMV5051U, HMV8051U
30" Double Models
27" Single Models
HMB50x0
27" Double Models30" Combination Models
30" Single Models
30" Single Models, Under Induction Cooktop 30" Single Models, Under Electric Cooktop 30" Single Models, Under Gas Cooktop
HMB80x0
HWD30x0UC HWD2750UCHWC800500
29
¹⁄₁₆"
36"
4
³⁄₁₆"
3
⅝"
3"
4
"
4¾"
28¼"
SUMP
1
1
/16"
6
3
/4"
2
3
/4"
Fitting/
Conduit
TOE KICK
TOE KICK
COOKTOP
OVEN
COUNTERTO
P
Heat shield: Self positioning – 2⅜" length, Minimum
required air clearance: 1"
24
⁷⁄₁₆"
27
¹⁄₁₆"
27¹⁄₁₆"
29¹⁄₁₆"
24⁷⁄₁₆"
36"
SUMP
4³⁄₁₆"4"4¹⁵⁄₁₆"
6¾"
1¹³⁄₁₆"
4¾"
TOE KICK
COOKTOP
OVEN
TOE KICK
COUNTERTOP
3"
28¼"
Fitting/
Conduit
³⁄₁₆"
27
¹⁄₁₆"
29
¹⁄₁₆"
24
⁷⁄₁₆"
36"
SUMP
COOKTOP
OVEN
COUNTERTOP
Gas
Connection
4
³⁄₁₆"
3
¹³⁄₁₆"
3"
5
¹¹⁄₁₆"
6¾"
1⅛"
4¾"
28¼"
TOE KICK
⅜"
The built-in oven can be installed below the induction cook-
top as long as there is an air clearance of 1" between the bot-
tom of the cooktop and the top of the oven.
The built-in oven can be installed below the electric cooktop
as long as there is no contact between the bottom of the
cooktop and the top of the oven.
The built-in oven can be installed below the gas cooktop as
long as there is no contact between the bottom of the cook-
top and the top of the oven.
Note: Dimensions based on standard countertop height (36¾" with 4" toe kick including base plate).
Technical Details,
Dimensions and
Installation
122 | Technical Details, Dimensions and Installation
Technical Details, Dimensions and Installation | 123










