Page 17 of 51 Vetta Head Assembly Instructions Rev D1
a. Attach the Expansion Slot Cover Plate
Attach the expansion slot cover (30-51-0040) to the chassis using 6 6-32x.375 black oxide
screws (30-00-0375) These screws are to be tightened to a torque setting of 6 in-lbs. Do not
over tighten.
b. Insert the Line Filter board and Secure Ground
Mount the AC receptacle PCB assy (50-00-4001) to the chassis. Ensure that the plastic
receptacle passes through the hole in the sheet metal (see figure below). Secure using 3 #6-32 x
.437 Phillips screws w/ captive washers (30-00-0607) and 2 #6-32 x .625 Phillips screws w/
captive washers (30-00-0610). NOTE: the 2 longer screws mount directly through the plastic
AC receptacle as shown below.
Expansion slot cover
6-32 screws
2 #6-32 x .625 screws (30-00-0610),
mount through holes in AC receptacle.
Tighten to 6-8 in/lbs.
Ensure that plastic
receptacle passes
through hole in sheet
metal
3 #6-32 x .437 screws
(30-00-0607), mount
directly to holes in PCB.
Tighten to 6-8 in/lbs
torque.
The line filter PCB assy comes with a pre-attached
grounding cable. Attach cable to the stud as shown using
a #6 screw (30-00-0607). Tighten to 6-8 in/lbs. Attach
grounding label (40-25-0015) to area indicated.