User Manual

20
Part Names and Functions
fig.25
PEAK Indicator
This lights up when the signal is at before cliping.
If the PEAK indicator lights up frequently, turn down
the E.LEVEL knob. Also check the LOW, HIGH,
BRILLIANCE, and AMBIENCE knob settings; if
raised, try reducing these settings. If in spite of
these measures the PEAK indicator continues to
light up, lower the output level of the device
connected to the INPUT jacks or set the LEVEL
switch to +4 dBu.
EFFECT ON/OFF Pedal
Each press of the pedal switches the
effects on or off.
EFFECT ON/OFF
Indicator
This lights up when
effects are on.
MANUAL/MEMORY Pedal
Select the unit between MANUAL,
which produces the sound of the panel
knob settings unchanged, and
MEMORY, where settings have been
stored in advance.
Functions differ according to the Pedal
mode settings; make the most
appropriate setting for your particular
application.
MANUAL/MEMORY Pedal
Operation (p. 11)
MEMORY Number Indicator
(14)
The indicator for the currently selected
MEMORY number (14) lights.
The indicator flashes while the CE-20 is
in write standby; the indicator flashes
more rapidly while the write operation is
in progress.
SELECT Button
This changes the
memory 14.
WRITE Button
Press this to store
settings in
MEMORY.
POWER Indicator
This lights up when the
power is on.
MANUAL Indicator
This lights up when set to MANUAL.
MEMORY Indicator
This lights up when set to MEMORY.
When MEMORY is selected, the indicator flashes
whenever knob setting values are changed or when
the CE-20 is in write standby; the indicator flashes
more rapidly while the write operation is in progress.
Lit
Not Lit
Not Lit
Lit
When at MANUAL When at MANUAL