Maintenance
Lamp Replacement
Tools required:
Clean oil-free cloth
Cleaning alcohol
Position lamp tree so lamps are readily accessible.
Disconnect the power supply from the COMMAND LIGHT SHADOW.
Allow sufficient time for the lamps to cool. The surrounding metal lamp housings can cause
serious burns.
Grasp the lamp lens bezel firmly, release the latch that holds the lamp bezel in place. Use
caution, the lamp bezel and lens may fall if not properly grasped.
Caution: be certain that the lamp is cool to the touch before handling. Do not touch the lamp
directly. Use a clean oil-free towel to handle the lamp. The lamps operate at high temperatures.
Handling the lamps directly leaves minute traces of skin oils that cause localized hot spots that
can lead to early lamp failure. Lamp surfaces may be cleaned with alcohol.
Latch the bezel making sure that the weather stripping is properly fitted.
Cleaning
The COMMAND LIGHT SHADOW is constructed with corrosion resistant aluminum and
stainless steel fasteners. To further enhance corrosion resistance all exposed surfaces receive a
powder coated paint finish. To assure years of trouble free service periodically clean all external
surfaces with a mild detergent solution and a gentle spray of water. Do not use a high-pressure
washer, which will force water into sensitive electric circuitry.
Lamp lenses may be cleaned with any commercially available glass cleaner.
Actuator is a sealed unit and does not require adjustment or lubrication.
Periodic cleaning of all pivot points on the COMMAND LIGHT SHADOW with a moisture
displacing cleaner and soft bristle brush, without disassembly, to remove accumulated dirt and
debris will minimize wear.