User's Manual
Table Of Contents
- general description
- Description
- Indications for Use
- Intended Use
- Contraindications
- Programmer Warnings and Cautions
- General
- Electrostatic Discharge (ESD)
- S-ICD System Warnings and Cautions
- General
- Use of Other Medical Therapies/Diagnostic Procedures
- Electromagnetic Interference (EMI) Outside the Hospital Environment
- S-ICD System Clinical Investigation
- Potential Adverse Events
- Setup of the Q-TECH Programmer
- Packaging
- Programmer Controls and Connections
- Charging the Programmer
- Using the Q-TECH Programmer
- Turning the Programmer On
- Changing the Programmer Volume Level
- Placing the Programmer in Suspend Mode
- Turning the Programmer Off
- Using the Programmer Touch Screen
- Using the Wand
- Navigation
- Screen Header
- Navigation Bar
- Restarting the Programmer
- Configuring the Q-TECH Programmer
- Configuring Programmer Settings
- Date and Time Format
- Time Zone
- Language Preference
- Printer Selection
- Programmer Software Version
- Modes of Operation for the Q-TECH Programmer
- Online Behavior
- Offline Behavior
- Modes of Operation for the SQ-RX Device
- Shelf Mode
- Therapy On Mode
- Therapy Off Mode
- Connecting and Disconnecting from the SQ-RX Device
- Scanning For SQ-RX Devices
- Connecting to the SQ-RX Device
- Connecting to an SQ-RX Device in Shelf Mode:
- Ending a Patient Session
- Programming the SQ-RX Device at Implant
- Entering Electrode Information
- Creating the Patient Chart
- Automatic Setup
- Programming Therapy Parameters
- Defibrillation Testing
- Performing an SQ-RX Follow-up
- Sensing Configuration and Automatic Setup
- Viewing SQ-RX Device Status
- Viewing Stored Episodes
- Printing Reports from the Programmer
- Printing Reports
- Summary Report
- Captured S-ECG Report
- Episodes Report
- S-ECG Features
- S-ECG Rhythm Strip Markers
- S-ECG Scale Settings
- Capture and View S-ECG Strips
- Utilities Menu
- Acquire Reference S-ECG
- Capture All Sense Vectors
- Beeper Control
- Manual Setup
- Smart Charge
- Additional Programmer Functions
- Rescue Shock
- Manual shock
- S-ICD System Magnet Model 4520
- Charging the Programmer
- Cleaning the Programmer
- Service
- Maintenance Check
- Safety Measurements
- Programmer End of Life
- Inability to Print
- No Printer Available
- Touch Screen Inactive while Connected to AC Power
- Loss of Communication with Printer
- Inability to Communicate With the SQ-RX Device
- Federal Communications Commission (FCC) US
- Essential Performance
- EMI/RFI
- Declarations tables
- Table 3: Declaration Electromagnetic Emission
- Table 4: Declaration Electromagnetic Immunity Part 1
- Table 5: Declaration Electromagnetic Immunity Part 2
- Table 6: Recommended Separation Distances
- Table 7: EMI/RFI Information: Programmer–to–pulse generator
- Table 8: EMI/RFI Information: Programmer–to–printer (Bluetooth®)
- Specifications
- Table 9: Product Guidelines
- Table 10: Specifications
- Table 11: Nominal Specifications
- Definition of package label symbols
- Table 12: Packaging Symbols: Q-TECH Programmer
- Table 13: Packaging Symbols: Q-TECH Programmer Wand
- Warranty
- Limited Warranty
58
QTECH™ PROGRAMMER: OPERATION
2. Select the Reset Beeper button to suspend audible beeping tones triggered by an
alert condition (Figure 48). If the alert condition is not corrected, the audible beeping
tones will be reactivated during the next automatic S-ICD System self-check.
Figure 48: Resetting the Beeper
3. The disable Beeper feature is enabled when ERI is reached or EOL occurs. If desired,
select disable Beeper when ERI or EOL occurs. Beeper tones are permanently
disabled.
Note: If beeper is disabled alert conditions will not trigger audible tones.
Manual Setup
Manual Setup enables the user to perform the electrode integrity test and select the electrode
sensing conguration and gain setting in the SQ-RX device.
1. From the Utilities screen (accessible from the Main Menu screen), select the
Manual Setup button. The Impedance Test screen appears (Figure 49).
2. Select the Test button to perform the electrode integrity test.