User's Manual
Table Of Contents
- general description
- Description
- Indications for Use
- Intended Use
- Contraindications
- Programmer Warnings and Cautions
- General
- Electrostatic Discharge (ESD)
- S-ICD System Warnings and Cautions
- General
- Use of Other Medical Therapies/Diagnostic Procedures
- Electromagnetic Interference (EMI) Outside the Hospital Environment
- S-ICD System Clinical Investigation
- Potential Adverse Events
- Setup of the Q-TECH Programmer
- Packaging
- Programmer Controls and Connections
- Charging the Programmer
- Using the Q-TECH Programmer
- Turning the Programmer On
- Changing the Programmer Volume Level
- Placing the Programmer in Suspend Mode
- Turning the Programmer Off
- Using the Programmer Touch Screen
- Using the Wand
- Navigation
- Screen Header
- Navigation Bar
- Restarting the Programmer
- Configuring the Q-TECH Programmer
- Configuring Programmer Settings
- Date and Time Format
- Time Zone
- Language Preference
- Printer Selection
- Programmer Software Version
- Modes of Operation for the Q-TECH Programmer
- Online Behavior
- Offline Behavior
- Modes of Operation for the SQ-RX Device
- Shelf Mode
- Therapy On Mode
- Therapy Off Mode
- Connecting and Disconnecting from the SQ-RX Device
- Scanning For SQ-RX Devices
- Connecting to the SQ-RX Device
- Connecting to an SQ-RX Device in Shelf Mode:
- Ending a Patient Session
- Programming the SQ-RX Device at Implant
- Entering Electrode Information
- Creating the Patient Chart
- Automatic Setup
- Programming Therapy Parameters
- Defibrillation Testing
- Performing an SQ-RX Follow-up
- Sensing Configuration and Automatic Setup
- Viewing SQ-RX Device Status
- Viewing Stored Episodes
- Printing Reports from the Programmer
- Printing Reports
- Summary Report
- Captured S-ECG Report
- Episodes Report
- S-ECG Features
- S-ECG Rhythm Strip Markers
- S-ECG Scale Settings
- Capture and View S-ECG Strips
- Utilities Menu
- Acquire Reference S-ECG
- Capture All Sense Vectors
- Beeper Control
- Manual Setup
- Smart Charge
- Additional Programmer Functions
- Rescue Shock
- Manual shock
- S-ICD System Magnet Model 4520
- Charging the Programmer
- Cleaning the Programmer
- Service
- Maintenance Check
- Safety Measurements
- Programmer End of Life
- Inability to Print
- No Printer Available
- Touch Screen Inactive while Connected to AC Power
- Loss of Communication with Printer
- Inability to Communicate With the SQ-RX Device
- Federal Communications Commission (FCC) US
- Essential Performance
- EMI/RFI
- Declarations tables
- Table 3: Declaration Electromagnetic Emission
- Table 4: Declaration Electromagnetic Immunity Part 1
- Table 5: Declaration Electromagnetic Immunity Part 2
- Table 6: Recommended Separation Distances
- Table 7: EMI/RFI Information: Programmer–to–pulse generator
- Table 8: EMI/RFI Information: Programmer–to–printer (Bluetooth®)
- Specifications
- Table 9: Product Guidelines
- Table 10: Specifications
- Table 11: Nominal Specifications
- Definition of package label symbols
- Table 12: Packaging Symbols: Q-TECH Programmer
- Table 13: Packaging Symbols: Q-TECH Programmer Wand
- Warranty
- Limited Warranty
60
QTECH™ PROGRAMMER: OPERATION
Figure 50: Gain adjustment
• 1x Gain (± 4 mV): 1x Gain should be selected when the signal amplitude is large
enough to cause clipping when the 2x gain is selected.
• 2x Gain (± 2 mV): 2x Gain should be selected when the signal amplitude is small
enough to allow use of a more sensitive setting without causing
clipping of the captured signal. The 2x gain selection amplies
the signal twice as much as the 1x gain selection.
To program the manually selected sense conguration:
1. Select the Program button to save the sense vector and gain settings.
2. The Acquire Reference S-ECG process is automatically enabled during the Manual
Setup Process. Select the Continue button to acquire a reference S-ECG. A
conrmation screen will appear when the captured reference S-ECG is acquired
(Figure 51).
3. Select the Continue button.