- Labeling knowledge . Read this manual thoroughly before implanta
- For single patient use only . Do not reuse, reprocess, or rester
- Backup defibrillation protection . Always have external defibril
- Resuscitation availability . Ensure that an external defibrillat
- Patch leads . Do not use defibrillation patch leads with the pul
- Separate pulse generator . Do not use this pulse generator with
- Handling
- Avoid shock during handling . Program the pulse generator Tachy
- Do not kink leads . Do not kink, twist, or braid the lead with o
- Handling the lead without Connector Tool . For leads that requir
- Handling the terminal while tunneling . Do not contact any other
- Appropriate lead connections . When implanting a system which us
- Programming and Device Operations
- Post-Implant
- Protected environments . Advise patients to seek medical guidanc
- Magnetic Resonance Imaging (MRI) exposure . Do not expose a pati
- Diathermy . Do not subject a patient with an implanted pulse gen
- Ensure PTM is enabled . If desired, ensure that Patient Triggere
- Magnet Response set to Inhibit Therapy . Once the Patient Trigge
- General
- PRECAUTIONS
- Clinical Considerations
- Sterilization and Storage
- If package is damaged . The blister trays and contents are steri
- If device is dropped . Do not implant a device which has been dr
- Storage temperature and equilibration . Recommended storage temp
- Device storage . Store the pulse generator in a clean area away
- Use by date . Implant the pulse generator and/or lead before or
- Implantation
- Expected benefits . Determine whether the expected device benefi
- Evaluate patient for surgery . There may be additional factors r
- Lead compatibility . Prior to implantation, confirm the lead-to-
- Telemetry wand . Make sure a sterile telemetry wand is available
- Line-powered equipment . Exercise extreme caution if testing lea
- Replacement device . Implanting a replacement device in a subcut
- Do not bend the lead near the lead-header interface . Insert the
- Absence of a lead . The absence of a lead or plug in a lead port
- Electrode connections . Do not insert a lead into the pulse gene
- Defibrillation lead impedance . If total shocking lead impedance
- Shunting energy . Do not allow any object that is electrically c
- Do not suture directly over lead . Do not suture directly over t
- Device Programming
- Device communication . Use only the designated PRM and software
- STAT PACE settings . When a pulse generator is programmed to STA
- Biventricular pacing therapy . This device is intended to provid
- Pacing and sensing margins . Consider lead maturation in your ch
- Proper programming of the lead configuration . If the Lead Confi
- Proper programming of the shock vector . If the shock vector is
- Programming for supraventricular tachyarrhythmias (SVTs) . Deter
- AV Delay . To ensure a high percentage of biventricular pacing,
- Adaptive-rate pacing . Rate Adaptive Pacing should be used with
- Ventricular refractory periods (VRPs) in adaptive-rate pacing .
- Atrial Tachy Response (ATR) . ATR should be programmed to On if
- Threshold test . During a manual LV Threshold test, RV Backup Pa
- Left ventricular pacing only . The clinical effect of LV pacing
- Shock waveform polarity . For IS-1/DF-1 leads, never change the
- Tachy Mode to Off . To prevent inappropriate shocks, ensure that
- Atrial oversensing . Take care to ensure that artifacts from the
- ATR entry count . Exercise care when programming the Entry Count
- ATR exit count . Exercise care when programming the Exit Count t
- Proper programming without an atrial lead . If an atrial lead is
- Left ventricular lead configuration . Proper programming of the
- Left Ventricular Protection Period (LVPP) . Use of a long LVPP r
- Sensing adjustment . Following any sensing range adjustment or a
- Patients hear tones coming from their devices . Patients should
- Patient use of patient triggered monitor . Determine if the pati
- Patient initiate stored EGM . Consider having the patient initia
- Environmental and Medical Therapy Hazards
- Hospital and Medical Environments
- Mechanical ventilators . During mechanical ventilation, respirat
- Conducted electrical current . Any medical equipment, treatment,
- Internal defibrillation . Do not use internal defibrillation pad
- External defibrillation . It can take up to 15 seconds for sensi
- Lithotripsy . Extracorporeal shock wave lithotripsy (ESWL) may c
- Ultrasound energy . Therapeutic ultrasound (e.g., lithotripsy) e
- Electrical interference . Electrical interference or “noise” fro
- Radio frequency (RF) interference . RF signals from devices that
- Central line guidewire insertion . Use caution when inserting gu
- Home and Occupational Environments
- Follow-up Testing
- Explant and Disposal
- Supplemental Precautionary Information
- Potential Adverse Events
- Mechanical Specifications
- Items Included in Package
- Symbols on Packaging
- Characteristics as Shipped
- X-Ray Identifier
- Federal Communications Commission (FCC)
- Pulse Generator Longevity
- Warranty Information
- Product Reliability
- Patient Counseling Information
- Lead Connections
- CAUTION: Prior to implantation, confirm the lead-to-pulse genera
- CAUTION: If the Lead Configuration is programmed to Bipolar when
- Figure 2. Lead connections and setscrew locations, RA: IS-1, RV:
- Figure 3. Lead connections and setscrew locations, RA: IS-1, RV:
- Figure 4. Lead connections and setscrew locations, RA: IS-1, RV:
- Figure 5. Lead connections and setscrew locations, RA: IS-1, RV:
- Figure 6. Lead connections and setscrew locations, RA: IS-1, RV:
- Implanting the Pulse Generator
- CAUTION: The absence of a lead or plug in a lead port may affect
- CAUTION: Do not suture directly over the lead body, as this may
- WARNING: For leads that require the use of a Connector Tool, use
- Table 8. Lead measurements
- WARNING: For leads that require the use of a Connector Tool, use
- WARNING: Do not contact any other portion of the DF4–LLHH or DF4
- WARNING: When implanting a system which uses both a DF4-LLHH/LLH
- CAUTION: For IS-1/DF-1 leads, never change the shock waveform po
- CAUTION: Do not insert a lead into the pulse generator connector
- Figure 7. Inserting the torque wrench
- CAUTION: Insert the lead terminal straight into the lead port. D
- CAUTION: The absence of a lead or plug in a lead port may affect
- CAUTION: To prevent inappropriate shocks, ensure that the pulse
- CAUTION: Take care to ensure that artifacts from the ventricles
- CAUTION: If total shocking lead impedance during implant is less
- CAUTION: Patients should be tested for diaphragmatic stimulation
- CAUTION: To prevent inappropriate shocks, ensure that the pulse
- WARNING: Always have external defibrillation equipment available
- Induce the Patient’s Arrhythmia
- Perform the Induction
- Determine DFT
- Bidirectional Torque Wrench
- Loosening Stuck Setscrews
- Follow Up Testing
- For additional technical reference guides, go to
- Additional Technical Information
Meteorological Satellite, or the E arth Exploration Satellite Services and must accept interference that may be
caused by such stations, including interference that may cause undesired operation. This transmitter shall
be used only in accordance with the FCC Rules governing the Medical Device Radiocommunication Service.
Analog and digital voice communications are prohibited. Although this transmitter has been approved by the
Federal Communications Commission, there is no guarantee that it will not receive interference or that any
particular transmission from this transmitter will be free from interference. This transmitter operates between
402–405 MHz band and uses FSK modulation.
Wanded telemetry operates at 57 kHz and uses QPSK modulation.
CAUTION: Changes or modifications not expressly approved by Boston Scientific could void the user’s
authority to operate the equipment.
PULSE GENERATOR LONGEVITY
Based on simulated studies, it is anticipated that these pulse generators have average longevity to explant
as shown below.
The longevity expectations, which account for the energy used during manufacture and storage, apply at the
conditions shown in the table along with the following:
• Assumes 70 ppm LRL; DDDR mode; 100% biventricular pacing; 15% atrium pacing and 0.4 ms pacing
Pulse Width (RA, RV, LV); RA Impedance 500 ;sensorsOn.
• Projected longevity is calculated assuming 3 maximum energy charging cycles per year, including
automatic capacitor re-forms and therapeutic shocks. For the final year of device service, an additional
5 charging cycles are assumed to account for additional automatic capacitor re-forms as the device
approaches the Explant indicator. These calculations also assume 3-channel EGM Onset is set to On,
and that the pulse generator spends 6 months in Storage mode during shipping and storage.
39