Safety Information

Page 10 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
P
2.7.1
Basic requirements
Fuse “F1” integrated part of the
equipment
P
Instructions when protection relies on building
installation
N/A
2.7.2
Faults not simulated in 5.3.7
N/A
2.7.3
Short-circuit backup protection
By building installation
P
2.7.4
Number and location of protective devices ........... :
One fuse “F1” located in line
conductor
P
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel ................................ :
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
No safety interlocks
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
Protection against extreme hazard
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches, relays and their related circuits
N/A
2.8.7.1
Separation distances for contact gaps and their
related circuits (mm) .............................................. :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
P
2.9.1
Properties of insulating materials
P
2.9.2
Humidity conditioning
P
Relative humidity (%), temperature (°C) ............... :
93%, 40C, 120 hrs