Boulderlink Messages
Each component in the system can send a message to the
preamplier which is then shown on its display. This is particularly helpful
in conrming the operation status of each power amplier in a multiple
amplier system. Typical messages on a 2010 Preamplier are as follows.
“AMP 1 Error” means that an internal power supply has failed and the
amplier has turned itself off to protect the speakers from damage.
“AMP 1 DC” means that it has muted due to a DC offset voltage
being detected at its inputs.
“AMP 1 HOT” means that the amplier has muted due to a higher
than normal temperature condition on the heat sinks.
“AMP CLIP” means that the amplier’s output has momentarily
reached its voltage limitation.
“1 OFFLINE” means that the slave is no longer responding via
Boulderlink. Its Boulderlink cable may have become disconnected, or the
mains power has been disconnected.
“1 ONLINE” means that the slave is now responding via Boulderlink
in a normal manner and has been recognized by the master.