Flush Wall Installation
▼
►
▼
▼
HEADER: A DOUBLE HEADER
OR PLACING THE HEADER
VERTICALLY IS RECOMMENDED
STANDOFF 12” (305mm)
HEIGHT ABOVE TOPOF
THE FIREPLACE
FIRST 13-1/2” (343mm)
NON-COMBUSTIBLE
FINISHED WALL
TOP OF THE
FIREPLACE
Figure 14
Combustible Surround Installation
▼
▼
▼
▼
▼
▼
2 X 4
HEADERS
STANDOFFS
COMBUSTIBLE MANTLE
FINISHED WALL
13-1/2” (343mm)
NON-COMBUSTIBLE MATERIAL
SUPPLIED WITH FIREPLACE
NON-COMBUSTIBLE MATERIAL
Figure 15
Framing
Fireplace framing can be built before or after the replace is set
in place. Framing should be positioned to accommodate wall
covering and replace facing material. The replace framing
should be constructed of 2 x 4 lumber or heavier. The framing
headers may rest on the replace standoffs. Refer to Figure 13
for minimum framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMING METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
▲
►
▼
◄
◄
►
A
B
C
DVLL/DVTL
A 36-7/8 in. (937mm)
B 54-1/2 in. (138.4cm)
C 17-1/16 in. (433mm)
Figure 13
Framing dimension "A" includes a 12 in. (304 mm)
clearance for standoffs on rebox. After installing rebox
into framing, the nished wall surface must cover the
12 in. (304mm) opening above the rebox. Board provided
with replace.
ATTENTION: If a base or mantel is not used and the appliance is
installed directly on carpeting, tile or other combustible material other
than wood ooring, it shall be installed on a metal or wood panel
extending the full width and depth of the appliance. The vertical
dimension in Figure 13 must be adjusted when a metal or wood
panel is placed beneath the appliance.
CAUTION: If the joints between the nished wall and the replace
surround (top and sides) are sealed, a 300°F minimum sealant
material must be used. These joints are not required to be sealed.
Only non-combustible material (using 300°F minimum adhesive if
needed), can be applied as facing to the replace surround.
Finishing
Finish the walls with the material of your choice. Figure 4 on page 8
shows the minimum vertical and corresponding maximum horizontal
dimensions of mantels or other combustible projections above the
top front edge of the replace. Only non-combustible materials may
be used to cover the metal replace face.
INSTALLATION