Attention: Cold climate installation recommendation:
When installing this unit against a non-insulated exterior
wall, it is recommended that the outer walls be insulated to
conform to applicable insulation codes.
Vent Runs
In planning the installation for the replace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring.
The appliance can be mounted on any of the following surfaces:
1. A at, hard combustible surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact all
four (4) perimeter edges on the bottom of the unit and under the
center leg supports. Two more supports spaced evenly for front
and back may be required pending local code.
Vertical, 90° Elbow With Horizontal Termination
▼
◄
◄
▲
▼
▲
3” (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
61-5/8”
(156.52cm)
VENT CAP/
THIMBLE
WALL
FIRESTOP
Figure 16
IMPORTANT:
MINIMUM HEIGHT OFF THE TOP REQUIREMENTS
DVLL & DVLT - MUST USE a 2 ft. (610 mm) vertical vent pipe as
the rst section BEFORE installing the elbow.
Vertical, 90° Elbow To
Horizontal Out The Wall
◄
►◄
►
◄
◄
90°
ELBOW
VENT
CAP
WALL
FIRESTOP
A
PIPE LENGTH
B
C
A B C
6 in.
11-3/4 in. to 12-3/4 in.
(298mm to 323mm)
4-3/4 in. to 6-1/4 in.
(121mm to 159mm)
9 in.
14-1/4 in. to 15-3/4 in.
(362mm to 400mm)
7-3/4 in. to 9-1/4 in.
(197mm to 235mm)
12 in.
17-1/4 in. to 18-3/4 in.
(438mm to 476mm)
10-3/4 in. to 12-1/4 in.
(273mm to 311mm)
Figure 17
VENTING FIREPLACE