Owner`s manual
29843-2-0612Page 30
FINISHING THE WALL
Finishing The Wall For DF414BL DF41W Series &
DF41EHPBL Decorative Front
A minimum of 5/8 in. (15.8mm) is required from the bottom of the
replace to the top of the hearth extension material.
A minimum of 1/8 in. (3mm) is required from the side of the unit
to combustible material.
◄
5/8” (15.8mm)MINIMUM
FROM BOTTOM OF UNIT
TO TOP OF HEARTH
EXTENSION MATERIAL
55-1/2” x 13-1/2”
NON-COMBUSTIBLE BOARD
1/8” (3mm) MINIMUM
FROM SIDE OF UNIT
TO COMBUSTIBLE MATERIAL
Figure 44
Finishing The Wall For DF41W Series, DF41EHPBL, DF414BL
Decorative Front With Finishing Materials Less Than 1 in.
(25.4mm) Thick - Figure 45
Stop nishing materials at the top and bottom of the unit.
Finishing materials up to 1 in. (25.4mm) thick may come up to
the sides of the unit. The Optional Front will overlap the nishing
materials.
►
▼
◄
▲
24-1/4”
(616mm)
51”
(129.5cm)
5/8” (15.8mm) MINIMUM
FROM BOTTOM OF UNIT
TO TOP OF HEARTH
EXTENSION MATERIAL
Figure 45
Finishing The Wall for DF414BL, DF41W Series, & DF41EHPBL
Decorative Front With Finishing Materials Greater Than 1 in.
(25.4mm) Thick
For nishing materials over 1 in. (25.4mm) thick, center the unit side
to side in a 26 in. x 53-34 in. (660mm x 136.5cm) opening. The front
will t inside the nishing material.
Stop Finishing Materials 1 in. (25mm from the top of the unit. This
will allow 3/8 in. (10mm) of space for lifting the front to unhook and
remove it.
Stop Finishing Materials 3/4 in. (19mm) from the bottom of the unit.
26”
(660mm)
53-3/4”
(136.5cm)
◄
◄
1” (25.4mm) MINIMUM
FROM FINISHING MATERIAL
TO TOP OF UNIT
3/4” (19mm) MINIMUM
FROM FINISHING MATERIAL
TO BOTTOM OF UNIT
Figure 46