FIREPLACE DIMENSIONS
DVLL NAT DVLL LP DVTL NAT DVTL LP
Input Btu/hr Maximum 34,500 31,500 34,500 31,500
Btu/hr Minimum 18,000 20,500 17,000 16,700
KWH (Maximum) 10.1 9.2 10.1 9.2
(Minimum) 5.3 6.0 5.0 4.9
Orice #31, P209 #51, P210 3.10mm, P296 #51, P210
Min. Rate Screw #41 #52 #41 #52
Air Shutter Opening - Front 9/16 in. FULL OPEN 9/16 FULL OPEN
Height without standoff 24-1/4 in. (616 mm) 24-1/4 in. (616 mm) 24-1/4 in. (616 mm) 24-1/4 in. (616 mm)
Width 51-1/16 in. (129.7 cm) 51-1/16 in. (129.7cm) 51-1/16 in. (129.7cm) 51-1/16 in. (129.7cm)
Depth 15-13/16 in. (402 mm) 15-13/16 in. (402 mm) 15-13/16 in. (402 mm) 15-13/16 in. (402 mm)
Gas Inlet Shutoff Valve
(Pipe)
1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT
▲
►
▼
◄
A
F
G
H
I
►
J
◄
◄►
▲
▼
▲
▼
DIMENSIONS
in inches (metric)
DVLL(DVTL)
A
51-1/16
(129.7cm)
B
44-1/2
(113.0cm)
C
16-1/2
(419mm )
D
36-5/8
(930mm)
E
24-5/8
(625mm)
F
15-13/16
(402mm)
G
6-9/16
(167mm)
H
9-1/4
(235mm)
I
23-7/8
(606mm)
J
1-9/16
(40mm)
K
1-1/4
(32mm)
TOP VIEW
FRONT VIEW
RIGHT SIDE VIEW
▲
►
▼
◄
◄ ►
▲
▼
A
B
C
D
E
K
◄►
▲
▼
12” (305mm)
▼
▲
LEFT SIDE VIEW