Vent Pipe Clearance
Note:Maintainoneinch(1in.)ofclearancearoundverticalvent
pipe.See Figure 9.Forhorizontalvent,maintainaminimum1in.
clearancetothebottom,twoinchestothesidesofthevent,and3
in.clearancetocombustiblesabovetheventpipe.See Figure 10.
►
◄
VENT PIPE
1” (25mm) MINIMUM
CLEARANCE AROUND VENT PIPE
Figure 9
2” (50.8mm)
TOP OF VENT PIPE
4”
DIAMETER
FLUE
6-5/8”
DIAMETER
INTAKE VENT
3” (76mm)
1” (25.4mm)
Figure 10
INSTALLATION
Attention: Horizontal venting through a wall requires a wall
thimbleontheinteriorsideofthewallabovethepipe.
SPECIAL VENT SYSTEMS
ThefollowingventsystemsareacceptableforusewithDV(TL,LL)41FPseriesreplaces:
Simpson Duravent® GS 4" - 6 5/8"
Selkirk Direct-Temp® 4" - 6 5/8"
Security Secure Vent® 4" - 6 5/8"
EmpireFlexventKitDVVK-4F,refertopage30.