Owner`s manual

29843-5-1012Page 38
Figure 58
WIRING DIAGRAM
MOTOR
COMM.GLIGHTS
AUX
FAN
MAIN
PILOT
Learn
MOTOR COMM.
POWER
IPI
Continuous
Pilot
Off/On
Remote/Off
S I
ADJ.
(GND)
BLACK
ORANGE
GREEN
WHITE
BROWN
PILOT
(OPTIONAL)
ON/OFF
SWITCH
GAS CONTROL
VALVE
120V
EXTENSION
MODULE
ELECTRONIC
CONTROL MODULE
JUNCTION BOX
BATTERY
BACK-UP
ORANGE
WHITE
DVLL ONLY
Note: For"RF"FireplacemodelswithPremiumMulti-FunctionRemoteControl,Refertotheseparateinstructionsforoperationofthe
remotecontrolsystem.
MAINTENANCE INSTRUCTIONS
TROUBLESHOOTING
IMPORTANT:Allserviceandtrouble-shootingproceduresshould
beperformedbyanexperiencedqualiedservicetechnician.
Ifthepilotwillnotstaylit:
1. Conrmthatthesensorwire(white)andtheignitorwire(or-
ange)areproperlyconnectedtotheControlModule“S”and
“I”terminals.
2. ConrmthattheSparktoPilotburnerisproperlygroundedto
theGasControlValveandtheControlModule.
3. Checkthepowersourcefromthe6-voltpoweradaptororthe
BatteryBack-uppackconnectionandconditionofbatteries.
4. CheckthepositionoftheCONTINUOUSPILOTswitchonthe
ControlModule.IfmainburnerdoesnotcomeONwhenthe
manualswitchandremotecontrolisturnedON:
a. Conrmthatthepilotsparksandlights.
b. Checkthetwo(2)pinplasticconnectorsthatplugintothe
faceoftheGasControlvalve.
c. ConrmthattheGasControlvalveisproperlygrounded
totheControlModule.
OPTIONAL GAS CONVERSION KITS
PleasecontactyourdealerordistributorfortheproperConversion
kit for these replace models. Conversion kits will include com-
plete instructions, minimum rate screw, plus the pilot and main
burner orice for the gas type required.TheAF-4044Electronic
GasControlValveisconvertibletouseeithernaturalorpropane
gasbysimplyturningasmallRotaryknoblocatedatthefrontof
thegasvalve.Thisrotaryknobislocatedunderasmallrubber(or
aluminum)capandshouldonlybeadjustedwhenconvertinggas
type.
CAUTION: Thegastypehasbeenpre-setatthefactoryandmust
notbechangedunlessacompleteconversionismadewhichin-
cludeschangingofthegaspilotinjector,airshuttersettingsand
mainburnerorice.