Operating Manual

Operating Manual - Recce 360 mini (V2.0 20220524)
active (when devices are receiving the stream). It will not affect behavior when the camera is not
in active mode.
To summarize, the run time can be extended by:
Having no active streams from the camera
Turning off illumination
Enabling power saver while receiving
3.4.3 Thermal protection
The camera has two thermal protection mechanisms.
Thermal throttle
To prevent the camera from overheating while powered overheating protection is a gradual
thermal throttle. This will reduce the framerate as the camera heats up. The thermal throttle will
never lower the frame rate below 1 fps.
Thermal shutdown
Despite the thermal throttle, the camera might still overheat because of environmental
conditions or long run times when connected to a power supply. The thermal shutdown can
happen if:
Internal temperature above the threshold. When the camera has reached the maximum
thermal throttle level, and if this does not stabilize the temperature, the temperature
might reach a critical point. At this temperature, the camera is shut down to prevent
permanent damage to the camera and batteries.
Combination of internal temperature and runtime above the threshold. This protection is
configured to limit run time to approximately 10 hrs if the camera is run at room
temperature.
After thermal shutdown, the camera should be shut down (press button) and let it cool down
before charging or running it for a longer period.
3.5 Power down
To power down the camera, press the power symbol on top of the camera (top view - A). There
should be tactile feedback from the switch below the rubber (controls view - B) when pressed.
Keep pressing until the haptic feedback from the integrated vibration motor is felt. The motor will
vibrate three times.
3.6 Attaching accessories
Accessories can be attached to the tether/tripod mount (top view - C, bottom view - C). The
mounts have a standard internal thread 1/4x20. This is the same as a regular tripod thread.