4000/260 LF 4000/260 LFC Monochrome and Color Terminals User's Guide 598-0011148
Before using this information and the product it supports, be sure to read the general information under "Notices." It is the policy of Boundless Technologies, Inc. to improve products as new technology, components, software, and firmware become available. Boundless Technologies, therefore, reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed by Boundless Technologies in all parts of the world.
This guide... is a user's manual and contains all of the information necessary to install, setup, and use the 4000/260 LF product. More detailed information on programming using control codes and escape sequences, default strings and character sets, international language support, etc. can be obtained by calling the Boundless Technologies Hotline at: USA and Canada calls. . .. 1-800-231-5445 International calls. . . . . ..
Contents Contents Preface iii How to Connect/Disconnect the Terminal Notices Trademarks and Service Marks Electronic Emission Notices Safety Notices iv iv v v vi Introduction 7 Features Vertical Mount: Under-Desk Mount: Wall Mount: Physical Features Keyboards Display Fields Usage Notes Communications Receive Flow Control.
Contents Entry And Exit Printing Saving Parameters Movement Inside Menus Action Fields Dual Session Mode Setup Map Quick: Fl General: F2 Display: F3 Keyboard : F4 Keys: FS Ports: F6 Host: F7 Print: F8 Emulation: F9 ASCII Emulations ANSI Emulations Tabs: FlO Answerback: Fll Program: F12 Execute: Prt Sc Edit Fields Glossary of Terms Page Reset Terminal Parameters Session Parameters " " 23 23 23 24 24 24 25 27 28 29 30 31 33 33 34 34 34 35 36 36 37 38 38 39 39 39 39 Desk Accessories 40 Desk Accessory
How to Connect/Disconnect the Terminal iii Preface This product is in conformity with the protection requirements of EU Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Boundless Technologies cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non- Boundless Technologies option cards.
How toConnect/Disconnect the Terminal iv How to Connect/Disconnect the Terminal To Connect: To Disconnect: First, turn everything OFF. First, turn everything OFF. ~ < Remove signal cables from receptacles. Attach signal cables to receptacles. _--JC=~rIIl . __,--_ -L_ --_-:-=-nfr=--=--~-- > '-' , -~~~ 111 <:1 , , ~ ~ ~I Remove all cables from devices. Attach power cord to outlet. 1_ _ ) ~> ~ I > (1:----1=-=_ Turn device ON. You may now take it with you.
Trademarks and Service Marks v Trademarks and Service Marks The following terms are trademarks of these companies: ADDS Viewpoint Centronics CSA DEC VT320/220/ 100 IBM MENTOR SCO TV! 925 UL WYSE WYSE 50/50+ / 60 / 120/ 150 Boundless Technologies, Inc. Centronics Data Computer Corporation Canadian Standards Association Digital Equipment Corporation International Business Machines Corporation Boundless Technologies, Inc. Santa Cruz Operations, Inc. TeleVideo Systems, Inc. Underwriters Laboratories Inc.
Safety Notices Safety Notices Da..ger Notices A danger notice indicates a hazard that could possibly cause death or serious personal injury. The following danger notices are used throughout this manual. A DANGER: To prevent a possible electrical shock when installing . . . the device, ensure that the power cord for that device IS unplugged before installing signal cables.
Safety Notices vii Introduction This guide contains information on all areas of the 260lf product. However, not all 260lf terminals are equipped with all the features in this publication (i.e. the descriptions of color features do not apply to the monochrome product). The terminal you have purchased features a small footprint logic controller and a VGA monitor, while providing support for both ASCll and ANSI terminals, PC-Term and SCOTM Console and AT386.
2 Features Personality: ADDS- Vicwpointt'" (ASCII emulation) WyseTM60, Wyse 50/50+ (ASCII emulation) DECTM VT-320, VT-220, VT-lOO (ANSI Emulation) PC Terminal (PC Term) SCQ-Console (ANSI Emulation) AT386 (ANSI Emulation) TVI925 (ASCII emulation) Intercolor (ANSI Emulation) Wyse 325, Wyse 350 (ASCII emulation) Display: Dual session available in full or split screens VGA monitor (Color or Monochrome).
3 Vertical Mount: 1. Insert the tabs into the corresponding slots as shown (left). 2. While applying pressure on the bracket, slide the bracket toward the front of the of logic unit until it clicks into place. Under-Desk Mount: 1. Ensure that the bracket is securely fastened under the desk in the position shown. You may use the wood screws supplied with the bracket if the mounting surface is particle board or wood. r F~~~='- i, ,~~~' 2.
4 Wall Mount: 1. Ensure that the bracket is securely fastened to the wall in the position shown. You may use the wood screws supplied with the bracket if the mounting surface is particle board or wood. IIII ,'I"I II I iY)}- 2. 3. --jill II ' ~o I , I ~ Position the logic unit on the bracket by directing the slots in the unit around the tabs on the bracket. While pressing the logic unit towards the wall, slide the unit downwards until it clicks into place.
5 Physical Features 1. Power Switch - press the orange button to its recessed position to turn the unit "on." Press again to turn the unit "off." 1 - '. Leave the terminal's power switch (1) in the off position "0" until power and keyboard connections are made The Canadian Standards Association (CSA) recommends that the power outlet be near the terminal and easily accessible at alltimes. -_.~©j_~I,I~I'®E':~_--I- @~e~~.1 II I,.I®\•. Power 2 2. 3. 4. 5. 6. 7. 8. 9.
6 Keyboards The monochrome terminal supports only the "PC-style" keyboards which include the PC 10 I fl 02-key and Compact PC l O'l-key keyboard. The color terminal supports two styles of keyboards: "PC-style" and "ANSI-style" keyboards. The keyboard layout is divided into functional key groups (as described below). The ANSI - style keyboard differs from the PC-style keyboard mainly in that it features 20 function keys, a set of PF-keys, and a different style numeric keypad.
7 ANSU~;eyboar
8 Usage Notes The following notations and symbols are used in this manual: • • Ctrl-F1: the two keys, Ctrl and Fl, arc to be pressed simultaneously. Ctrl, F1: the two keys, Ctrl and Fl, are to be pressed in succession. • 1-num or 1-alph: specifies that the number must be generated either from the numeric or alphanumeric • keypads. 23h: the number 23 is represented in hexadecimal (hex) notation. · 1~~1 applies to ASCll emulations only: ADDS-VP, Wyse 50+, Wyse 60, PC Term, and TVI-925.
9 Communications This terminal is equipped with three communications ports. The two serial ports are intended for connection to either a host (or modem), an alternate input device such as a scanner, or a serial printer. (The EIA port has both an RJ45 and a DB25 interface; either, but not both, can be used.) The last port is a Centronics-compatible printer port which could be used with a parallel printer or other output device (such as a cash drawer) connected to a parallel interface.
10 Refer to the Installation chapter for details on the connection of the DB25 EIA port or the RJ45 EIA port to serial devices (hosts, modems, or printers). The optional RS-422 and current loop communications interface is only available for this DB25 EIA port. Host/Printer Port 1 (RJ45) This port, labeled "EIA," located to the right of the "Aux" port, is designed to connect to a host (computer or modem) or a serial printer and can operate from 110 to 115,200 baud.
11 Host/Printer Port 2 This port, labeled "Aux," is designed to connect to a second host connection (computer or modem), a scanner or other input device, or a serial printer, and can operate from 110 to 38,400 baud. This port also uses an RS-232 C interface via an RJ45 female connector and is configured as a DCE device.
12 Terminal To Modem (or DeE Host) Refer to the diagram below to understand why a nun modem adapter may be needed when connecting the AUX serial port to a modem or a DCE host. The EIA port will connect directly without a nun modem since it is a DTE device. Host Modem L·········· pln2~ Receive Transmit pmz _ ~ln3 Receive I,oo_-J ... ~ l ~i~~ Transmit 1·--'~~01 I~=.;-;C I RJ'S liiil connec'2' D iI ~'J ~ __.. DCE Receive Modem (-~ ~~ c; il E !:: __ mna pin3 /-------..
13 Screen Display And Pages This terminal offers a variety of screen lengths including 26, 44, or 49 lines. These numbers include the top and bottom status lines (or label line), as well as the lines used to display data. A "page" of terminal memory represents the total number of lines that can be accessed, whether or not they are all viewable on the screen at once. Refer to Appendix A for the number and lengths of pages available for your set-up.
14 Visual Effects Of Screen And Page Lengths The combination of page and screen lengths influence the number of displayable data lines. For example, if the page length is "50" (25 x 2), and the screen length is 44 lines, the number of data lines that are visible at any one time is 43, with no label line. The other line is used for the top status line. On a 49 line screen, 48 of the 50 data lines are visible at one time.
15 Installation This section provides a "walk-through" approach to the installation of your terminal. This will enable you to physically connect the terminal to a printer, one or two host computers/modems, scanner or another input device. If necessary, you will also be able to configure the Setup menu to suit your requirements and preferences. The terminal is designed to provide great configuration flexibility.
16 Step 4 • No Printer Option If you did not opt to install a printer (do not complete steps 9E, 9F, 9G, or 9H), you must set the Printer portion of the Host/Printer selection in the Quick (F1) Setup menu to "None." Choose the combination of Host/Printer that properly represents which terminal port you are connecting the host to, and "None" as the printer. For example, if the EIA port is connected to the host or modem, the setting would be "EIA/None.
17 2. In the Setup Quick (F1) menu, set the Host portion of the "Host/Printer" selection to EIA, without changing the current Printer option ("EIA/xxxx"). The Printer will be set in another connection procedure if needed. 3. In the Ports (F6) menu, set the proper communications settings for the EIA Baud, EIA Data Format, EIA Parity Check, EIA Recv, and EIA Xmt selections. See the Setup chapter for more detailed information on the individual settings. Connection B• DYE Host On AUI 1.
18 Step 12 - Save Parameters Finally, remember to save your Setup parameters in permanent memory, so that they can be recovered if the terminal is powered down. When you exit the Setup menu, the prompt "Save all? (YIN)" flashes. To save parameters, press "Y." Another way to save parameters is to perform a "Save Terminal" operation, while in the Exec (Prt Sc) menu of Setup. Both methods will save the parameters in both sessions, as well as those that are common to both.
19 Host/Printer Connection Guide A CAUTION: Do not (un)plug in electrical storm. SES1-EIA (DTE) DTE Host* ~ i c'lJ' PA~ 'ElJYJ~: -- "\ ~ f PAR SES2-AUX (DCE) ; I _·PAIL "Auil " EtA -=~_~ I ! 'l;id -, J -_:::: Connection A: Connection B: Connect a null modem adapter between the host cable and the EIA port. Connect the host cable directly to the AUX port. Not applicable. DCE Host orModem L·········· 8 .
20 SES1·EIA (DTE) DTE Serial Prlnter** :__ -- S~$2·AUX (DCE) P~R I ~AVX"~ -- PAR 'EAR 'ADX ~-"'r--- f;A -:~~ ~- -e , -I \~) ~i Connection E: Connection F: Connection G: Connect a null modem adapter between the serial printer cable and the EIA port. Connect the serial printer cable directly to the AUX port. This is an option if you connect a parallel-to-serial converter between the serial printer cable and the PAR port. Not applicable. Not applicable.
21 Common Setups TERMINAL TERMINAL D!:lZ5 FiJ45 RJ4~ OB2~ -.- DB25 DAR--/IAiiX:I~:1 \ -tiA ~ - PAR RJ45 RJ4S 'rAUX FtA 06.25 f IA . ~OST DCE SERIAL PRINTER Sessions=One HostjPrinter=EIA/Aux EIA Baud, etc. matches the host Aux Baud, etc. matches the printer EtA Modem Controt=On Sessions=One HostjPrinter=EIA/ Para Aux Baud, Aux DataFormat, etc. matches the host, and aux. device. Alt Input Data=On .. The Aux port can be configured as a DTE device or a null ..
Installation User Settings Use the chart below to document your system and terminal settings: Parameters Number of sessions Host/Printer (Session 1)* Host/Printer (Session 1)* Emulations (Session 1) Emulations (Session 2) Host 1: Baud Data Bits Stop Bits Parity Parity Check Flow Control (In)** Flow Control (Out)*** Modem Control Examples: Your Settings: 2 EINPara AuxlNone ADDS-VP VT-300-8 9600 8 1 None Off Xon-Xoff Xon-Xoff On Dual Host mode only, press CTRL-Enter (kpd): Host 2: Baud Data Bits Stop
Setup 23 Setup The Setup menu is your control panel for this terminal. It permits you to configure the terminal to communicate with the host computer as well as to suit your personal preferences. Overview The Setup menus have been designed to allow maximum flexibility with a minimum investment of time. Thirteen menus provide you with the flexibility and the features below contribute to ease of use: The Quick menu is the first screen upon entry.
Setup 24 An exception to this is function/edit key and answerback message programming. Once edited in Setup, the changes are saved regardless of the way in which you exit Setup. Movement Inside Menus F1 through F12 - Select the menu that corresponds to the function key. The Print Scm key is available to access the "EXEC" menu. These keys are always active within Setup. The keys are labeled at the top of each menu.
Setup Setup Map Fl Parameters Available Menu Key Quick (Not all will displayfora given emulatign, keyboard, orvideo mode) Emulation Baud Rate Vlux Data Format HosUPrinter ~ux F2 F3 General Display F4 Keyboard FS (:J.
Setup I r F7 Host Comm Mode Recv Send Block Term Null Suppress Local Send ACK Send Reqion ~It Input Data Recv Send Line Term Send End F8 Print IPmt Line Term Prnt Mode Pmt Block Term Secondary Recv Prnt Reqion F9 ~---,,'Emulation ~ttribute Paqe Edit WPRT Underline Briqht Video WPRT Intensity WPRT Blink Enhanced Attributes WPRT Reverse Disolav NV Labels FlO ~, ~abs - Fll ~nswerback Fl2 Program Key Program Key Dir Execute Save Terminal Save Session Recall Terminal Rec
Setup 27 Quick: F1 ~\IFIQuick'i Genrl F2 F3 Disp F4 FS F6 F7 F8 F9 FlO Kybd Keys Ports Host Print Emul Tabs Fll Fl2 AnsBk Prog F13 Exec I ~ulation = Wyse-60] --I~EIA Baud Rate Parameters Comm Mode = Full Duplex = 9600 Aux Baud Rate = 9600 Enhanced = On EIA Data Format = 8/l/N Aux Data Format = 8/11N Language =U.S.
Setup 28 General: F2 This chapter lists all possible parameters for each menu, and all possible choices for each parameter. Depending on the emulation selected, the keyboard type, and the key mode (ASCII or ScanCode), Setup will only present the valid set of parameters and choices in each menu. Emulation: select the "personality" of the terminal. See the Quick menu on page 27. Enhanced: Choose whether the terminal can respond to commands beyond the limitations of the current emulation.
Setup 29 Display: F3 Page Length: [24,25,42,43,48,50,84,86,96,100, (168), (172), (192), (200), *24, *25, *42, *43] Select the number of lines per page. As many as four pages (0-3) may be available, but the number of pages in memory depends on the memory/page configuration, number of lines per page, the firmware version, the type of emulation, and whether 80-0nly is selected for columns. The total lines used (Lines/Page x # of Pages) will not exceed 218. See Page Configurations in Appendix A.
Setup 30 Keyboard: F4 Language: [US, U.K., Danish, Finnish, French, German, Norwegian, Portuguese, Spanish, Swedish, Dutch, Belgian-Flemish, French-Canadian, Italian, Latin-American, Swiss-French, Swiss-German] Choose the language that matches the keyboard. Char Set Mode: [PC, ANSI, ASCII] Choose character sets used for 20-7Fh (GL) and AO-FFh (GR). In VT emulations, the default is ANSI.
Setup 31 Keys: F5 Enter Key: [CR, GR-LF, TAB] Select the code the enter key in the numeric keypad transmits. Return Key: [CR, CR-LF, TAB] Select the code the return key on the main alphanumeric keypad transmits. Alt Key (left): [Meta, Legend, Funct, Scroll-Lock, Alt Key] Select the way in which the left ALl key behaves. In ANSI emulations, Compose is available as a selection instead of Legend. The Alt Key selection refers to the right Alt key.
Setup 32 ANSI Keyboard Disconnect: [Disabled, Shifl-F5] Choose to allow the keystroke that will generate a modem disconnect on the ANSI keyboard or to disable the Disconnect function. If"Fl to F5 keys" selection is set to Fkey in Setup, the Disconnect function will be remapped to Ctrl-Shift-F5.
-----------~----- Setup 33 Ports:F& EIABaud Rate: [115200,76800,57600,38400,19200,9600,4800,2400, 2000,1800,1200,600,300,150,110] See Quick menu on page 27. EIA Data Format: [7/1/N, 7/1/0, 7/1/E, 7/1/M, 7/1/S, 7/2/N, 7/2/0, 7/2/E, 7/2/M, 7/2/S, 8/1/N, 8/1/0, 8/1/E, 8/1/M, 8/2/N, 8/2/0, 8/2/E] See Quick menu on page 27. EIA (Aux) Parity Check: [On, Off] Choose whether the parity bit will be checked.
Setup 34 Local: [Off, On] Select whether keyed data is interpreted locally by the terminal and not sent to the host. Data sent by the host is lost, if Local is on. The ability to print data is not affected by this mode. Send Block Term: [, ] Select which character will indicate the end of a block. The choices above are for ASCll emulations. ANSI emulations have the following choices: [None, FF]. 'I.ilsl'" ~.
Setup 35 Selects the speed at which function keys and labels are programmed by the host. Fast mode will increase the speed for Wyse 50 compatibility, but will limit the amount of space in each function key and answerback message to 8 bytes. Edit keys are not available for programming in fast mode. Changing this selection will default all function keys, edit keys, and function keys labels. Save Labels: [Off, On] When on, labels that are downloaded by the host will be saved in non-volatile memory.
Setup 36 Tabs:F10 -- I F4 F6 F8 F5 F7 FlO] Fll Fl2 PrtSc F9 Kybd Keys Ports Host Print Emut!abs AnsBk Prog Exec Parameters - I I DefaultTabs I FI F2 F3 Quick Genrl Disp -- "0 ------- IAuto InitTa:bs =0U I io zo 1111111.111.,1111.1.,11111 T T T ----- T T T so .. J.l'II""'~ ""'"IIIJII"I'II~IIIIII T T T T T T IT T T T ..;..,..,....t.,...,..J" ....... 1.,.. " .. :l, .... ".,........ ,.t.. 70 80 90 100 110 120 130 Choices ~ On t-7,J.
Setup 37 Program: F12 F3 F4 F5 F6 F7 F8 F9 FlO FII ~ PrtSe F2 Quick Genrl Disp Kybd Keys Ports Host Print Ernul Tabs AnsB Prog Exec IFI I Parameters l_Key~Fl] i Program ~ FlKey , Key Dir ~ Comm Dependent Text: Label:~==-_ I I ~~ Bytes Remaining: 0542 Choices F' F5 F6 F7 F8 F9 FlO FII FI2 Fl3 Fl' FI5 FI' I 1'~-.l.
Setup • • 38 To program a carriage return or line feed into the key text field, press Ctrl-M or Ctrl-J, respectively. To program the "Print Screen" key to perform a local print screen (page) function: In the key text field, press Ctrl-[ and then P. Next, set the "Key Dir"=Screen option.
Setup 39 Glossary of Terms Some of the terms that are used in the Exec (PrtSc) menu are defined below. Page Reset Page resets are executed when the session or terminal is reset or defaulted. When a page reset is performed, it affects all pages, and the following events occur: the page is erased, the cursor is homed, and scrolling regions are defaulted. All line attributes (such as double-high/wide, locked lines) are reset to normal.
Desk Accessories Desk Accessories This terminal features five desk accessories, which can be accessed one at a time through pop-up windows. Desk Accessory Menu To display this pop-up window to choose any of the five desk accessories, press Ctrl ~. F1 =Clock F2 = Calendar F3 F4 F5 =Calculator =ASCII Chart = Menu ESC = Exit Desk Accessory Mode Desk Accessory Menu Function keys F1-F5 are used to display the clock, calendar, calculator, ASCII chart, and diagnostic menu, respectively.
Desk Accessories 41 Exiting ADesk Accessory To exit any window and restore the original screen: A Press F11 on the ANSI keyboard. ~J Press Esc on a PC keyboard. Inhibiting Access Access to desk accessories can be inhibited by selecting "Disabled" for "Desk Acc" in the Keys (F5) Setup menu. Calendar This displays a calendar for any month from the years 1900 to 2099. The current date is displayed at the bottom. The keys below control the calendar that is displayed.
Desk Accessories 42 Clock The clock menu (shown below) contains seven lines which can be modified. Use the following keys to make changes: Up- or down-arrow keys - select a line. The line is highlighted. Left- or right-arrow keys - select a field on the chosen line. The selected field is now highlighted. Spacebar- move "up" through options available for this field. Shift-Spacebar - move "down" the options. Enter (kpd) - revert to the default setting for the current field.
Desk Accessories Calculator The numeric keypad located on the right side of your keyboard will serve as your calculator. See the figures below to relate the display to the keys on the numeric keypad that control it. The calculator can process up to 10 digits to the left of the decimal point, and up to 9 to the right. When a number or number operator is pressed, it is momentarily highlighted on the display.
Desk Accessories 44 ASCII Chart Upon entering the ASCII Chart Desk Accessory, the decimal, octal, hexadecimal, binary, and ASCII representations of the character under the cursor are displayed in the pop-up window (as shown for the NULL character in the image at the top of the right column).
Desk Accessories Color Utility The Color Utility (260lfc only) is used to temporarily remap Colors and attributes on screen. Changes make to any of the pre-defined palettes with this utility cannot be saved. To define your own color combinations, use the provided soft palettes. To alter the color mapping for an attribute, use the up and down arrow keys to highlight one of the sixteen available attributes.
46 Compose ANSI-Multinational Compose Sequences Composed Character 3-Key Sequence 2-Key Sequence Quotation mark Number/pound Apostrophe At Left bracket Backslash 'iSP 'iSP )) A- SP \SP ¢ Right bracket Circumflex Grave accent Left brace Pipe Right brace Tilde Inverted! Cent £ Pound ¥ Yen § Section n © Currency Copyright Feminine ordinal Left angle brackets Degree # @ [ \ { I } !! Description ++ 'SP AA (( II /< A- ) -SP !I C/ CI L L= yy= S! SO XO CO A « OA SP * 2 II ~ Q % Y
Compose Composed Character i A A A A A A fE y E E E E i r f 'i N 6 6 6 6 6 CE 0 U U 0 0 Y b a a Ii a a a ce c; e e e e 1 f I 'i n 6 6 6 6 6 CE 0 U U G U y Description Inverted? A grave A acute A circumflex A tilde A umlaut A ring AE ligature C cedilla E grave E acute E circumflex E umlaut I grave I acute I circumflex I umlaut N tilde grave acute circumflex tilde umlaut OE ligature slash U grave U acute U circumflex U umlaut V umlaut German double s a grave a acute a circumflex a tild
Compose ANSI-ISO Latin-1 Compose Sequences Composed Character ® x "j y If (I) III o e Description No break space Pipe Logical not Soft (syllable) hyphen Registered trademark Macron Three-fourths Division sign Multiplication sign Acute accent Cedilla Diaeresis (umlaut) Yacute yacute Capital Icelandic thorn Small Icelandic thorn Capital Icelandic Eth Small Icelandic Eth 3-Key Sequence 2-Key Sequence SPSP !~ RO 34 xx Y' y' TH th -D "iSP 'Y 'y 48
Local Key Local Key Scan Code Mode Action Keyboard Toggle Caps-Lock No Caps Lock Toggle Num-Lock No Num Lock Toggle Scroll-Lock' No Scroll Lock Toggle Auto Prinf Yes Ctrl-Print Scm Toggle Block-Mode Yes Shift-Ctrl-Pause Toggle Monitor Mode Yes Shift-Ctrl-1 (kpd) Toggle Ins/Replace No Ctrl-I nsert Instant Screen Saver" Yes Ctrl-Shift-* (kpd) Compose Lead-in" No Shift- Funct Lead-in" No Ctrl- Meta Lead-in" No Alt (left) Scroll-Lock" Yes Shift-
50 Continued Action Scan Code Mode Keyboard Toggle Session Yes Ctrl-Enter (kpd) Enter Desk Accessory Mode Yes Ctrl-~ Enter Setup Mode Yes Ctrl-Scroll Lock Exit Setup Mode Yes Pause Enter Clock" Yes Ctrl+,F1 Enter Calendar" Yes Ctrl-~,F2 Enter Calculator" Yes Ctrl-~,F3 Enter ASCII Chart" Yes Ctrl-~,F4 Enter Diagnostic" Yes Ctrl-~,F5 Exit Any Desk Accessory Yes Esc Next Page 12 No Ctrl-Page Down Previous Page 12 No Ctrl-Page Up Display Page 0 13 No Ctrl-O\lns Displa
51 Page Configurations· Single Host Mode Lines per Page Number ofPages in80-0nly Columns Number of Pages in 80 or 132Columns 24 4 2 48 2 1 96 1 *24 2 (24/72) 2 (24/32) 25 3 2 50 1 1 *25 2 (25/71 2 (25/31) 42 2 1 84 1 *42 2 (42/54) 43 2 1 86 1 *43 2 (43/53) When a page length (in the firstcolUmn) is preceded by an asterisk (*), a total of two pages will be available.
Note To Installer 52 Note To Installer This equipment complies with the FCC Regulation for Class A devices, Subpart J of Part IS. Shielded, grounded interface cables were used on all ports for FCC radiated emission testing. The manufacturer is not responsible for any violation of the FCC Regulation for Class A devices that is caused by unauthorized modification of the equipment, or caused by equipment installation not in accordance with the instructions in this manual.