Datasheet

Features
Size: 8 mm diameter, 10 mm length
Balanced and symmetrical TRIGARD
®
design
High surge current rating
Stable breakdown throughout life
Long life
Fail-Short available
RoHS compliant*
Applications
Telecommunications electronics
Industrial electronics
Consumer electronics
Characteristics
2028 Series Long Life Heavy-Duty 3-Electrode Gas Discharge Tube
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
Test Methods per ITU-T (CCITT) K.12 Class 3 and IEC 61643-311.
Characteristic
Model No.
2028-23 2028-25 2028-35 2028-42
DC Sparkover ±20 % @ 100 V/s 230 V 250 V 350 V 420 V
Impulse Sparkover
100 V/µs (Typical/99 %)
1000 V/µs (Typical/99 %)
< 450 V/550 V
< 650 V/750 V
< 450 V/550 V
< 650 V/750 V
< 700 V/800 V
< 850 V/950 V
< 850 V/950 V
< 1050 V/1150 V
Impulse Transverse Delay ............................... 1000 V/µs ..........................................................< 75 ns
Insulation Resistance (IR) ............................... 100 V ................................................................> 1 GΩ
Capacitance..................................................... 1 MHz ...............................................................< 2 pF
Glow Voltage ................................................... 10 mA ................................................................~ 70 V
Arc Voltage ...................................................... 1 A .....................................................................~ 10 V
DC Holdover Voltage
1
.................................... 135 V ................................................................< 150 ms
Impulse Discharge Current
2
........................... 30,000 A, 8/20 µs .............................................. 1 operation
20,000 A, 8/20 µs .............................................. 10 operations
5,000 A, 10/350 µs ............................................ 1 operation
200 A, 10/1000 µs ............................................. 300 operations
20 A, 10/1000 µs ............................................... 1500 operations
Alternating Discharge Current ......................... 20 Arms, 1 second ............................................ 10 operations
Operating Temperature ............................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1)................................................................................................ 40 / 90 / 21
Notes:
1
Network applied.
2
The Rated Impulse Discharge Current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line
to ground.
At delivery AQL 0.65 Level II, DIN ISO 2859.
*RoHS COMPLIANT
Bulk Packaging Specifi cations
2028-xx-ALF ................... 250 pcs. per tray
2028-xx-CLF ..................... 50 pcs. per tray
2028-xx-C2LF ................. 100 pcs. per tray
2028-xx-C2FLF............... 100 pcs. per tray
How to Order
2028 - nn - x n F LF
Model Number
Designator
Voltage (Divided by 10)
23 = 230 V 35 = 350 V
25 = 250 V 42 = 420 V
Leads
A = No Leads /
Cassette Applications
C = 1.0 mm
Lead Shape
(See Product Dimension Drawings)
Fail-Short Option
Blank = Standard Product
F = With Fail-Short Mechanism
RoHS Compliancy
LF = RoHS Compliant Product
Asia-Pacifi c:
Tel: +886-2 2562-4117
Fax: +886-2 2562-4116
Europe:
Tel: +41-41 768 5555
Fax: +41-41 768 5510
The Americas:
Tel: +1-951 781-5500
Fax: +1-951 781-5700
www.bourns.com