Datasheet

Features
Size: 8 mm diameter, 10 mm length
High current rating
Low capacitance and insertion loss
Fail-short option available
RoHS compliant*
UL Recognized
Applications
Telecommunications equipment
Industrial equipment/electronics
Consumer electronics
Characteristics
2046 Series Heavy-Duty 3-Electrode Gas Discharge Tube
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
Test Methods per ITU-T K.12 and IEC 61643-311.
Characteristic
Model No.
2046-09 2046-14 2046-20 2046-23 2046-25
DC Sparkover ±20 % @ 100 V/s 90 V 145 V 200 V 230 V 250 V
Impulse Sparkover
100 V/µs
1000 V/µs
< 600 V
< 700 V
< 500 V
< 700 V
< 500 V
< 700 V
< 600 V
< 700 V
< 600 V
< 700 V
Insulation Resistance (IR)
NOTE 1
............................50 / 100 / 250 Vdc ................................................. > 10 GΩ
Glow Voltage ...........................................................10 mA ..................................................................... ~ 70 V
Arc Voltage ..............................................................1 A .......................................................................... ~ 10 V
Glow-Arc Transition Current .................................................................................................................... < 1 A
Maximum Capacitance ............................................1 MHz ..................................................................... < 2 pF
Maximum Impulse Discharge Current .....................20,000 A, 8/20 µs ................................................... 1 operation
10,000 A, 8/20 µs .................................................. 10 operations
Nominal Alternating Discharge Current ...................20 A, 50 Hz, 1 second ............................................ 1 operation
Impulse Life .............................................................200 A 10/1000 µs .................................................. 130 operations
DC Holdover Voltage
NOTE 2
................................................................................................................... < 150 ms
Operating Temperature ............................................................................................................................ -30 to +85 ºC
Storage Temperature ............................................................................................................................... -40 to +115 °C
Climatic Category (IEC 60068-1)............................................................................................................. 40 / 90 / 21
Notes:
• UL Recognized component, UL File E153537.
At delivery AQL 0.65, level II DIN ISO 2859
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground voltage.
• Discharge current rating is total current equally divided between Each Line To Ground (ELTG).
Note 1: DC Sparkover Voltage IR Measuring Voltage
90 V .........................................50 V
145–400 V ...............................100 V
420–600 V ...............................250 V
Note 2: Network Applied
DC Sparkover Voltage DC Holdover Voltage
90–145 V .................................52 V
200–250 V ...............................135 V
350–600 V ...............................150 V
*RoHS COMPLIANT
Characteristic
Model No.
2046-35 2046-40 2046-42 2046-47 2046-60
DC Sparkover ±20 % @ 100 V/s 350 V 400 V 420 V 470 V 600 V
Impulse Sparkover
100 V/µs
1000 V/µs
< 700 V
< 800 V
< 800 V
< 900 V
< 800 V
< 900 V
< 900 V
< 1000 V
< 1000 V
< 1100 V

Summary of content (2 pages)