Datasheet

Parameter Symbol
CD214-
Unit
B120 B120L B130 B130L B140 B150 B160 B170 B180 B190 B1100
Repetitive Peak
V
RRM
20 20 30 30 40 50 60 70 80 90 100 V
Reverse Voltage
Reverse Voltage V
R
20 20 30 30 40 50 60 70 80 90 100 V
Maximum RMS Voltage V
RMS
14 14 21 21 28 35 42 49 56 63 70 V
Avg. Forward Current I
O
1A
Forward Current,
Surge Peak I
surge
30 25 30 25 30 30 30 30 30 30 30 A
(60 Hz, 1 cycle)
Typical Thermal
R
θJL
20 35 20 35 20 20 20 25 25 25 25 °C/W
Resistance**
Storage Temperature T
STG
-55 to +150 °C
Junction Temperature T
J
-55 to +125 °C
CD214A-B120 ~ B1100 Schottky Barrier Rectifier Chip Diode
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Features
RoHS compliant*
SMA package
Surface mount
Very low forward voltage drop
General Information
The markets of portable communications, computing and video equipment are challenging the semiconductor industry to develop increasingly
smaller electronic components.
Bourns offers Schottky Rectifier Diodes for rectification applications, in compact chip package DO-214AC (SMA) size format, which offer PCB
real estate savings and are considerably smaller than competitive parts. The Schottky Rectifier Diodes offer a forward current of 1 A with a
choice of repetitive peak reverse voltage of 20 V up to 100 V.
Bourns
®
Chip Diodes conform to JEDEC standards, easy to handle on standard pick and place equipment and their flat configuration
minimizes roll away.
Parameter Symbol
CD214-
Unit
B120 B120L B130 B130L B140 B150 B160 B170 B180 B190 B1100
Forward Voltage (Max.)
V
F
0.5 0.41 0.5 0.41 0.5 0.7 0.7 0.79 0.79 0.79 0.79 V
(I
f
= 1 A)
Typical Junction
C
T
110 100 110 100 110 110 110 30 30 30 30 pF
Capacitance*
Reverse Current (Max.)
I
R
500 1000 500 1000 500 500 500 500 500 500 500 µA
at Rated V
R
)
Electrical Characteristics (@ T
A
= 25 °C Unless Otherwise Noted)
How To Order
CD 214A - B 1 30 L LF
Common Code
Chip Diode
Package
• 214A = SMA/DO-214AC
Model
B = Schottky Barrier Series
Average Forward Current (I
o
) Code
1 = 1 A (Code x 1000 mA = Average Forward Current)
Reverse Voltage (V
R
) Code
30 = 30 V
40 = 40 V
100 = 100 V
Forward Voltage Suffix (Applies to B120L & B130L only)
L = Low Forward Voltage V
f
(B120L & B130L only)
No Space in P/N = Not Low Forward Voltage
Terminations
LF = 100 % Sn (RoHS Compliant)
Asia-Pacific:
Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
Europe:
Tel: +41-41 768 5555 • Fax: +41-41 768 5510
The Americas:
Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
Absolute Ratings (@ T
A
= 25 °C Unless Otherwise Noted)
* Measured at 1.0 MHz and applied reverse voltage of 4.0 V DC.
** Thermal resistance junction to lead.
*RoHS COMPLIANT
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.

Summary of content (6 pages)