Core Loss vs. Flux Density
10.0 ± 0.30
(.394 ± .012)
7.90
(.311)
TYP.
10.0 ± 0.30
(.394 ± .012)
6.50 ± 0.30
(.256 ± .012)
4R7
TYP.
3.30
(.130)
TYP.
3.40
(.134)
TYP.
3.30
(.130)
Features
Maximum height of 6.7 mm
Current up to 8 A
RoHS compliant*
Applications
Input/output of DC/DC converters
Power supplies for:
Portable communication equipment
Camcorders
LCD TVs
SRU1063 Series - Shielded SMD Power Inductors
Test Voltage ......................................0.1 V
.... 230 °C, 50 sec. max.
Operating Temp. .......... -40 °C to +125 °C
(Temperature rise included)
Storage Temperature .. -40 °C to +125 °C
Resistance to Soldering Heat
...............................+260 °C for 10 sec.
Moisture Sensitivity Level ...................... 1
.................. N/A
Core ......................Ferrite DR and RI core
Wire ..............................Enameled copper
Terminal ...................................... Ag/Ni/Sn
Rated Current ...Ind. drop 35 % typ. at Isat
Temp. Rise ........40 °C max. at rated Irms
Packaging .....................500 pcs. per reel
Materials
Product Dimensions
REF.
REF.
REF.
REF.
7.20
(.283)
3.80
(.150)
REF.
3.80
(.150)
1.80
(.071)
REF.
1.80
(.071)
REF.
1.80
(.071)
REF.
1.80
(.071)
7.20
(.283)
Recommended Layout
DIMENSIONS:
MM
(INCHES)
*RoHS COMPLIANT
* RoHS Directive 2002/95/EC Jan. 27, 2003 including
annex and RoHS Recast 2011/65/EU June 8, 2011.
Bourns
Part Number
Inductance
@ 100 KHz
Q
Ref.
Test
Freq.
(MHz)
SRF
Typ.
(MHz)
RDC
Max.
(mΩ)
I rms
Max.
(A)
I sat
Typ.
(A)
**K-
Factor
L (μH)
Tol.
(%)
SRU1063-1R6Y 1.6 ±30 13 7.96 65 9 8.00 10.00
133
SRU1063-2R2Y 2.2 ±30 10 7.96 65 11 7.50 8.50
95
SRU1063-4R7Y 4.7 ±30 11 7.96 30 14 5.50 5.70
68
SRU1063-100Y 10 ±30 14 2.52 18 38 3.80 4.00
49
SRU1063-150Y 15 ±30 12 2.52 14 42 3.20 3.40
41
SRU1063-220Y 22 ±30 15 2.52 10 60 3.00 3.20 33
SRU1063-330Y 33 ±30 12 2.52 8 105 2.20 2.40 26
SRU1063-470Y 47 ±30 10 2.52 6 150 1.40 1.60 22
SRU1063-680Y 68 ±30 8 2.52 5 210 1.20 1.35 20
SRU1063-101Y 100 ±30 12 2.52 4 320 1.10 1.20 15
Δ I (peak-to-peak ripple current, A),
determine core loss from Core Loss vs. Flux Density plot.
10
0
Electrical Schematic
Flux Density Bp-p (gauss)
100
1000
10000
10
100 1000
1 MHz
500 KHz
300 KHz
200 KHz
100 KHz
50 KHz
10000
1
0.1
Core Loss (mW)
WARNING Cancer and Reproductive Harm
www.P65Warnings.ca.gov
Specifications are subject to change without notice.
Users should verify actual device performance in their
specific
applications.
The products described herein and
this document are subject to specific legal disclaimers as
set forth on the last page of this document, and at
www.bourns.com/docs/legal/disclaimer.pdf

Summary of content (3 pages)