Datasheet

Features
n Superior circuit protection
n Overcurrent protection
n Blocks surges up to rated voltage limit
n High-speed performance
n Small SMT package
n RoHS compliant*
Applications
n RS-485 interfaces
n Exposed sense and data lines
n Factory automation
n Protection modules and dongles
n Process control equipment
n Test and measurement equipment
n General electronics
TBU-DF Series - TBU
®
High-Speed Protectors
*RoHS Directive 2015/863, Mar 31, 2015 and Annex.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
General Information
The TBU-DF Series of Bourns
®
TBU
®
products are low capacitance dual bidirectional high-speed Electronic
Current Limiters (ECLs), constructed using MOSFET semiconductor technology, and designed to protect
against faults caused by short circuits, overvoltage transients and faults in battery cells, up to rated limits.
The TBU
®
high-speed protector placed in the system circuit will monitor the current with the MOSFET detec-
tion circuit triggering to provide an effective barrier behind which sensitive electronics will not be exposed to
large voltages or currents during transient events.
The TBU
®
device is provided in a surface mount DFN package and meets industry standard requirements
such as RoHS and Pb Free solder reow proles.
TBU
®
Device
Line 1 I/O Line 1 I/O
Line 2 I/O Line 2 I/O
3
4
1
6
Absolute Maximum Ratings (@ T
A
= 25 °C Unless Otherwise Noted)
Symbol Parameter Part Number Value Unit
V
imp
Peak impulse voltage withstand with duration less than 10 ms
TBU-DF055-xxx-WH
TBU-DF085-xxx-WH
550
850
V
V
rms
Continuous A.C. RMS voltage
TBU-DF055-xxx-WH
TBU-DF085-xxx-WH
250
425
V
T
op
Operating temperature range -55 to +125 °C
T
stg
Storage temperature range -65 to +150 °C
T
amax
Maximum Ambient Temperature +125 °C
*RoHS COMPLIANT
LEAD FREE
*RoHS COMPLIANT
VERSIONS
AVAILABLE
LEAD FREE
VERSIONS ARE
RoHS COMPLIANT*
Electrical Characteristics (@ T
A
= 25 °C Unless Otherwise Noted)
Symbol Parameter Part Number Min. Typ. Max. Unit
I
trigger
Current required for the device to go from operating state to
protected state
TBU-DFxxx-050-WH
TBU-DFxxx-300-WH
TBU-DFxxx-500-WH
50
300
500
75
450
750
100
600
1000
mA
R
device
Series resistance of
the TBU
®
device
V
imp
= 550 V I
trigger
(min.) = 50 mA
V
imp
= 550 V I
trigger
(min.) = 300 mA
V
imp
= 550 V I
trigger
(min.) = 500 mA
V
imp
= 850 V I
trigger
(min.) = 50 mA
V
imp
= 850 V I
trigger
(min.) = 300 mA
V
imp
= 850 V I
trigger
(min.) = 500 mA
TBU-DF055-050-WH
TBU-DF055-300-WH
TBU-DF055-500-WH
TBU-DF085-050-WH
TBU-DF085-300-WH
TBU-DF085-500-WH
12
6
5
23
15
12
26
14
13
38
26
25
R
match
Package resistance matching of the TBU
®
device #1 - TBU
®
device #2 +0.5
t
block
Time for the device to go from normal operating state to protected state 1 µs
I
Q
Current through the triggered TBU
®
device
with 50 Vdc circuit voltage 0.5 mA
V
reset
Voltage below which the triggered TBU
®
device will transition to normal operating state 12 16 20 V
R
th(j-a)
Junction to ambient - FR4 using JESD51-3 board 125 °C/W
R
th(j-a)
Junction to ambient - FR4 using JESD51-7 board 50 °C/W
F5530
53802
Environmental Characteristics
Parameter Value
Moisture Sensitivity Level 1
ESD Classication (HBM) 1B
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov