Lever Type Dial Test Indicators
– BL-9 / BL-10
Please carefully review these instructions to ensure proper and accurate
use of your new Test Indicator.
This indicator is designed to provide a true reading when the
angle between the contact point and component is 12°.
Any configuration of an angle other than 12° needs the displayed
value to be corrected. For a position of 0°, the correct value is:
Maintenance
No special maintenance is required. The bearings of the indicator
must not be oiled.
Displayed value x 1.022" or 1.022mm
Contact Point with 12º Position