Use and Care Manual

10
TROUBLESHOOTING
Service Mode Procedures
PROCEDURE 1: CHECK FIRMWARE VERSION AND ERROR LOG:
1. Hold down the PAUSE/STOP button and Down arrow button together for 3 seconds while at the Welcome screen to enter the Console Setup
Mode.
2. The Console displays the TOTAL HOURS screen.
3. Push the Right arrow button to show the Console Firmware Version.
4. Record the code.
5. Push the Right arrow button four times.
6. The Console display shows “VIEW ERROR MSG NO” prompt.
7. Push the Up arrow button. The Console will display the “VIEW ERROR MSG YES” prompt.
8. The Console display shows “ERROR LOG VER2”. Push ENTER to access the log.
9. Push the Right arrow button and record the code shown.
10. Push the Right arrow button again and record the next code.
11. If you have recorded all the numbers, push the ENTER button and screen will display “ERROR LOG RESET YES”. Push Enter.
12. Press PAUSE/STOP to return to Welcome screen.
PROCEDURE 2: RESET MACHINE (workout data will be lost):
1. Hold down the PAUSE/STOP button and Down arrow button together for 3 seconds while at the Welcome screen to enter the Console Setup
Mode.
2. The Console displays the TOTAL HOURS screen.
3. Push the Right arrow button six times until the Console display shows the “RESET CONSOLE NO” prompt.
4. Press the Up arrow button and the screen will display RESET CONSOLE YES.
5. Push the Enter button.
6. Turn the machine off when the Console displays the “POWER CYCLE NOW.