Troubleshooting
&RQGLWLRQ3UREOHP Things to Check Solution
1RGLVSOD\SDUWLDOGLVSOD\XQLW
will not turn on
Check electrical (wall) outlet Make sure unit is plugged into a functioning wall outlet.
Check connection at front of unit &RQQHFWLRQVKRXOGEHVHFXUHDQGXQGDPDJHG5HSODFHDGDSWHURUFRQQHF-
tion at unit if either are damaged.
Power Switch 7XUQRQWKHSRZHUZLWKWKH3RZHU6ZLWFK
Check data cable integrity $OOZLUHVLQFDEOHVKRXOGEHLQWDFW,IDQ\DUHYLVLEO\FULPSHGRUFXWUHSODFH
cable.
Check data cable
FRQQHFWLRQVRULHQWDWLRQ
%HVXUHFDEOHLVFRQQHFWHGVHFXUHO\DQGRULHQWHGSURSHUO\6PDOOODWFKRQ
connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or otherwise damaged.
5HSODFH&RQVROHLIGDPDJHG
Console Display ,I&RQVROHRQO\KDVSDUWLDOGLVSOD\DQGDOOFRQQHFWLRQVDUH¿QHUHSODFHWKH
Console.
If the above steps do not resolve the problem, contact Customer Care for
further assistance.
8QLWRSHUDWHVEXW&RQWDFW+5
not displayed
+5FDEOHFRQQHFWLRQDW&RQVROH %HVXUHFDEOHLVFRQQHFWHGVHFXUHO\WR&RQVROH
+5FDEOHER[FRQQHFWLRQ %HVXUHFDEOHVIURPKDQGOHEDUVDQGFDEOHWR&RQVROHDUHVHFXUHDQG
undamaged.
Sensor grip %HVXUHKDQGVDUHFHQWHUHGRQ+5VHQVRUV+DQGVPXVWEHNHSWVWLOOZLWK
relatively equal pressure applied to each side.
Dry or calloused hands 6HQVRUVPD\KDYHGLI¿FXOW\ZLWKGULHGRXWRUFDOORXVHGKDQGV$FRQGXFWLYH
HOHFWURGHFUHDPKHDUWUDWHFUHDPFDQKHOSPDNHEHWWHUFRQGXFW7KHVHDUH
DYDLODEOHRQWKHZHERUDWPHGLFDORUVRPHODUJHU¿WQHVVVWRUHV
Static Handlebar If tests reveal no other issues, Static Handlebar should be replaced.
8QLWRSHUDWHVEXW7HOHPHWULF+5
not displayed
Chest Strap (optional) 6WUDSVKRXOGEH³32/$5
®
” compatible and uncoded. Make sure strap is
directly against skin and contact area is wet.
&KHFN8VHU3UR¿OH 6HOHFWWKH(GLW8VHU3UR¿OHRSWLRQIRUWKH8VHU3UR¿OH*RWRWKH:,5(/(66
+5VHWWLQJDQGPDNHVXUHWKDWWKHFXUUHQWYDOXHLVVHWWR21
Interference 7U\PRYLQJXQLWDZD\IURPVRXUFHVRILQWHUIHUHQFH790LFURZDYHHWF
5HSODFH&KHVW6WUDS ,ILQWHUIHUHQFHLVHOLPLQDWHGDQG+5GRHVQRWIXQFWLRQUHSODFHVWUDS
5HSODFH&RQVROH ,I+5VWLOOGRHVQRWIXQFWLRQUHSODFH&RQVROH
8QLWRSHUDWHVEXW7HOHPHWULF+5
displayed incorrectly
Interference 0DNHVXUHWKDWWKH+5UHFHLYHULVQRWEORFNHGE\DSHUVRQDOHOHFWURQLF
device in the left side of the media tray.
1R530UHDGLQJ&RQVROHGLV-
SOD\V³3OHDVH6WULGH´HUURUFRGH
Check data cable integrity $OOZLUHVLQFDEOHVKRXOGEHLQWDFW,IDQ\DUHFXWRUFULPSHGUHSODFHFDEOH
Check data cable
FRQQHFWLRQVRULHQWDWLRQ
%HVXUHFDEOHLVFRQQHFWHGVHFXUHO\DQGRULHQWHGSURSHUO\6PDOOODWFKRQ
connector should line up and snap into place.
Check magnet position (requires
shroud removal)
Magnet should be in place on pulley.
Check Speed Sensor (requires
shroud removal)
Speed sensor should be aligned with magnet and connected to data cable.
5HDOLJQVHQVRULIQHFHVVDU\5HSODFHLIWKHUHLVDQ\GDPDJHWRWKHVHQVRURU
the connecting wire.