C-100 USER’S GUIDE
The freedom to power your PAP device no matter where your world takes you! Your PAP device doesn’t have to keep you from enjoying the great outdoors... perfect for tent campers & use in RVs.
Table of Contents INTRODUCTION Product Specifications Package Contents Intended Use Compatibility Warranty 1 2 3 3 3 IMPORTANT NOTES Run Times ResMed Device Warning Humidifier Usage Power Backup Usage 4 4 5 5 ACCESSORIES Power Inverter 24V Power Converter 6-7 8 GETTING STARTED Control Board Identification The Power Meter Turning the Battery Pack On/Off Initial Battery Usage Using the Battery Pack Inside the Carrying Case 9 9 10 10 10 CHARGING THE BATTERY PACK Charging with AC Power Charging in a For
Table of Contents POWERING YOUR PAP DEVICE Introduction Connector Tips Respironics Devices ResMed Devices S9 Series Devices S8 Series & Older Devices Fisher & Paykel Devices DeVilbiss Devices 13 14 15 16 16 17 18 19 POWERING OTHER DEVICES 20 BATTERY PACK CARE INSTRUCTIONS Understanding Lithium-Ion Batteries Battery Pack Storage 21 21 SAFETY WARNINGS 22 DISPOSAL OF LITHIUM-ION BATTERIES 22
Introduction PRODUCT SPECIFICATIONS DIMENSIONS Size: 7.5” x 4.25” x 0.75” (L x W x H) Weight: 1.6 lbs ELECTRICAL Cell Type: Rechargeable lithium-ion Battery Capacity: 100 Wh Output Voltage Range: 9 - 12.6 V Output Current Range: 0 - 4.5 A (8A maximum) Power Gauge: Four stage LED display RECHARGE TIME 4-5 hours (per Battery Pack when fully discharged) BATTERY LIFE SPAN Under normal conditions the life span of the Battery Pack is generally around 400-500 charge/discharge cycles.
Introduction PACKAGE CONTENTS Your Battery Pack comes with the items listed below. If you are missing any of these items, please contact the company from whom you purchased your Battery Pack. CARRYING CASE AC POWER SUPPLY & POWER CORD BATTERY PACK(S) CONNECTOR TIPS Battery Pack is sold in a single or dual battery configuration package. Seven (7) unique connector tips. DC POWER PIGTAIL CORD DC INPUT CORD ACCESSORIES (SOLD SEPARATELY) 24V POWER CONVERTER For use with ResMed S9 devices only.
Introduction INTENDED USE Battery Packs are intended to provide external power to PAP (positive airway pressure) devices; however, when used in conjunction with a power inverter, they may also be used to power other small electronic devices such as smartphones, iPods, laptops and iPads. See page 20 for additional information regarding powering other devices.
Important Notes RUN TIMES Multiple factors will affect Battery Pack actual run times including, but not limited to, device type, whether a power inverter or power converter is used, pressure setting, and altitude. The use of heated humidification or heated tubing will significantly reduce expected run times. Average run times are based on Respironics System One and ResMed S-9 Series PAP devices with no heated humidification or heated tubing.
Important Notes HUMIDIFIER USAGE The use of heated humidification or heated tubing will significantly reduce the expected run time of the Battery Pack due to the amount of power required for the humidifier heating plate. To obtain optimal Battery Pack performance we recommend you forgo the use of heated humidification. Using cool or “passover” humidification will not reduce expected run times.
Accessories POWER INVERTER Sine wave power inverters are used to change direct current (DC) to alternating current (AC). Power inverters are universal and can be used with any device. Using a modified or pure sine wave power inverter in conjunction with the Battery Pack allows you to: Power Devices Without DC Capability To power a PAP device or other small electronic device that does not have DC capability, you must use a power inverter to complete the connection between the device and the Battery Pack.
Accessories POWER INVERTER CONNECTING THE 150 WATT INVERTER TO THE BATTERY PACK Connect the DC Input Cord to the DC Out Jack of the Battery Pack. Connect the Inverter Adaptor Cord to the side of the Inverter. Connect the cigarette lighter plug end of the Inverter Adaptor Cord into the DC Input Cord of the Battery Pack.
Accessories 24V POWER CONVERTER DC to DC power converters convert a source of direct current (DC) from one voltage to another (i.e. 24V to 12V). Power converters are generally proprietary to a specific device. Battery Power Solutions’ 24V Power Converter was specifically designed for use with ResMed S9 Series PAP devices and the C-100 Battery Pack. This single component connection provides a clean, efficient conversion from 24V to 12V direct current. See page 16 for additional information.
Getting Started CONTROL BOARD IDENTIFICATION The Control Board includes the DC In and DC Out Jacks, charge lights and the Power Meter, which indicates the remaining power level. E F G A B D C A DC In Jack D DC Out Jack G Power Meter B Power Meter Button E Charging Light C Full Charged Light F On Light The On Light (F) will be green when a device is plugged into the DC Out Jack (D). The Charging Light (E) will be red when the Battery is being charged.
Getting Started TURNING THE BATTER PACK ON/OFF The Battery Pack will turn on or off automatically when a device is plugged into or disconnected from the Battery Pack. If the Battery Pack stops functioning, reconnect the AC Power Supply to the Battery Pack to reset the internal circuitry. INITIAL BATTERY USAGE Before using your Battery Pack for the first time be sure to charge it fully using AC power (a wall outlet).
Charging the Battery Pack CHARGING WITH AC POWER (A WALL OUTLET) Connect the AC Power Cord to the AC Power Supply. Connect the Output Cable of the AC Power Supply to the DC In Jack of the Battery Pack. Connect the AC Power Supply to a wall outlet. After you have fully charged the Battery Pack the Full Charged light on the Control Board will display green. When charging is complete disconnect the AC Power Supply from the wall outlet and the Battery Pack.
Charging the Battery Pack CHARGING IN A VEHICLE The use of a power inverter in conjunction with the Battery Pack AC Power Supply allows you to safely and efficiently charge the Battery Pack via the cigarette lighter (power) socket of a vehicle. Connect the AC Power Supply to the Battery Pack. Connect the AC Power Supply to the Inverter. Plug the Inverter Adaptor Cord into the cigarette lighter (power) socket of the vehicle. Start the vehicle to begin charging.
Charging the Battery Pack DUAL BATTERY CONFIGURATION CHARGING If you are using the Battery Pack in the dual configuration you may charge both Battery Packs at the same time. Connect the DC Power Pigtail Cord to the DC In Jack of both Batteries. Connect the DC Power Pigtail Cord to the Output Cable of the AC Power Supply and follow the remaining charging instructions listed on page 11 (charging with AC power) or page 12 (charging in a vehicle).
Powering Your PAP Device CONNECTOR TIPS If your PAP device can be connected directly to the Battery Pack (Respironics and DeVilbiss PAP devices) you will need to insert one of the provided Connector Tips into the end of the DC Power Pigtail Cord in order to connect the PAP device to the Battery Pack. Locating the appropriate Connector Tip for your device: Compare the Connector Tips provided with your Battery Pack to the tip of the PAP device AC power supply.
Powering Your PAP Device RESPIRONICS DEVICES Respironics PAP devices may be connected directly to the Battery Pack. Connect the DC Power Pigtail Cord to the DC Out Jack of the Battery Pack. Note: If you are using the Battery Pack in the dual configuration, simply connect the DC Power Pigtail Cord to the DC Out Jack of both Battery Packs. Insert the appropriate Connector Tip into the female end of the DC Power Pigtail Cord. See page 14 for Connector Tip instructions.
Powering Your PAP Device RESMED DEVICES If you are using any device manufactured by ResMed you must use either a power converter or inverter to complete the connection between the device and the Battery Pack. Do not connect the Battery Pack directly to any ResMed device as doing so will damage the PAP device. RESMED S9 SERIES DEVICES Battery Power Solutions designed a 24V Power Converter specifically for use with ResMed S9 Series PAP devices. See page 8 for more information.
Powering Your PAP Device RESMED S8 SERIES & OTHER OLDER RESMED DEVICES ResMed S8 Series or other older ResMed PAP devices require the use of ResMed’s DC Power Converter or a power inverter in conjunction with the Battery Pack. Do not connect the Battery Pack directly to any ResMed device as doing so will damage the PAP device. CONNECTION USING RESMED DC POWER CONVERTER Connect the DC Input Cord to the DC Out Jack of the Battery Pack.
Powering Your PAP Device FISHER & PAYKEL DEVICES Fisher & Paykel PAP devices do not have DC capability and therefore require the use of a power inverter to complete the connection between the PAP device and the Battery Pack. CONNECTION USING BPS 150W POWER INVERTER Connect the DC Input Cord to the DC Out Jack of the Battery Pack.
Powering Your PAP Device DEVILBISS PAP DEVICES DeVilbiss PAP devices may be connected directly to the Battery Pack. Connect the DC Power Pigtail Cord to the DC Out Jack of the Battery Pack. Note: If you are using the Battery Pack in the dual configuration, simply connect the DC Power Pigtail Cord to both Battery Packs. Insert the appropriate Connector Tip into the female end of the DC Power Pigtail Cord. See page 14 for Connector Tip selection instructions.
Powering Other Devices The Battery Pack can be used to power other small electronic devices such as smartphones, iPads, portable DVD players, iPods, and laptops. If the electronic device operates from a 12V direct current and has a DC cable with a cigarette lighter plug you can connect the device directly to the Battery Pack via the DC Input Cord.
Battery Pack Care Instructions UNDERSTANDING LITHIUM-ION BATTERIES Rechargeable lithium-ion batteries have quickly become the emerging standard for portable power in consumer devices due to their light weight, high energy density, lack of memory effect, and charge longevity. They are also more environmentally friendly as they do not contain toxic materials such as Cadmium or Mercury.
Safety Warnings By purchasing, using or possessing any of Battery Power Solutions’ products, you are agreeing to hold harmless Battery Power Solutions, it’s subsidiaries, affiliates, owners, officers and employees from any and all claims or liability for any damage to any property or injury, illness or death of any person when such damage, injury, illness or death shall be caused in whole or in part from use of the product(s).
1-877-445-5228 info@batterypowersolutions.net www.batterypowersolutions.
CPAP BATTERY PACK USER’S GUIDE January 2014