User's Manual

If necessary, drill holes for the mounting screws in the wall or mounting box on which the reader unit will be
placed. Use the template provided.
1. Place the controller and power supply cable through the Grommit hole.
2. Drill the holes as indicated by the arrows.
NOTE: Make sure that you don't drill through the cable.
Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair if
the wiring is connected incorrectly. Read the instructions on the next page first.
**NNOOTTEE::
Tamper cable connection is optional.
30
30
WARRANTY
The miP5 comes with a 5 year warranty from the date of dispatch from BQT Solutions. The warranty is void if the
instructions contained within this manual have not been adhered to. See the BQT Solutions website for further terms
and conditions.
SPECIFICATIONS
Reader Output Wiegand
Power requirements 12Vdc
Current Consumption
Normal 110mA
Activated 120mA
Read range 20 - 60mm (0.8” – 2.4”)(typically)
Operating temperature -10ºC to +55ºC (14ºF to 131ºF)
Relative humidity 90% max, operating non-condensing
Reader dimensions 90mm x 90mm x 20mm (3.54" x 3.54" x 0.79")
Status LED’s Green and Red
Audible tone Tone on matching software key and wired external buzzer control
Colour Charcoal & Ivory
IP rating IP 67
Wall View
RED +12Vdc
BLACK GND
YELLOW BUZ
ORANGE LED
GREEN W0
WHITE W1
BROWN/W* TAMPER1
BROWN/W* TAMPER2
- 9 - - 2 -