Spec Sheet

3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties.
See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821;
7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238;
7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186;
2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas
®
and Hydrojet
®
are registered trademarks of Bradford White
®
Corporation.
430-B-0319
Commercial ASME Electric Water Heaters
The ASME Electric Models feature:
n A.S.M.E. Code Tank Construction—Standard.
n Immersion Thermostats—Immersion type for accurate temperature control
from up to 180°F (82°C) with manual reset high limit control.
n Factory Installed Hydrojet
®
Sediment Reduction System—Cold water
inlet sediment reducing device helps prevent sediment build up in the tank.
n Vitraglas
®
Lining—An exclusively engineered enamel formula that provides
superior tank protection from the highly corrosive effects of hot water. This
formula (Vitraglas
®
) is fused to the steel surface by firing at a temperature of
over 1600°F (871°C.
n Water Connections— Factory-installed true dielectric fittings extend water
heater life and simplify water line connections.
n Elements—screw in style. Low watt density INCOLOY
®
material helps to
minimize dry fire and prevents lime build up.
n Insulation System—Non-CFC foam covers the sides and top of the tank,
reducing heat loss. This results in less energy consumption, improved
efficiencies, and jacket rigidity.
n Protective Magnesium Anode Rod—Provides added protection against
corrosion for long-term, trouble-free service.
n Completely Pre-wired—With pressure lug terminal block eliminating need
for splicing or taping of wires.
n Hand Hole Cleanout—(20 (76L) thru 120 (454L) gallon models only).
n T&P Relief Valve—Installed.
n Low Restriction Brass Drain Valve—Durable tamper proof design.
n NSF Construction Available on All Models.
Photo is of
30A-36-3

Summary of content (4 pages)