Instruction manual

17
Maintenance continued-
without leaking and operates freely. The following maintenance should be
performed by a qualified service technician at the minimum periodic intervals
suggested below. In some installations, the maintenance interval may be
more frequent depending on the amount of use and the operating conditions
of the water heater. Regular inspection and maintenance of the water heater
will help to insure safe and reliable operation.
1. Annually, check the operation of the thermostat(s).
2. Bi-annually, check the seal around the heating elements for leaks. If there
is any sign of leaking, disconnect the power supply to the water heater
and contact the plumbing professional that installed this water heater or a
qualified service technician.
3. At least once a year, check the combination temperature and pressure
relief valve to insure that the valve has not become encrusted with lime.
Lift the lever at the top of the temperature-pressure relief valve several
times until the valve seats properly without leaking and operates freely.
4. If the combination temperature and pressure relief valve on the appliance
discharges periodically, this may be due to thermal expansion in a closed
water supply system. Contact the water supplier or local plumbing
inspector on how to correct this situation. Do not plug the combination
temperature and pressure relief valve outlet for any reason.
5. Monthly, drain the water heater through the drain valve until the water
runs clear to remove silt and sediment.
6. A sacrificial anode rod has been installed to extend tank life. The anode
rod should be inspected periodically (every 2 years) and replaced when
necessary to prolong tank life. Water conditions in your area will
influence the time interval for inspection and replacement of the anode
rod. Contact the plumbing professional who installed the water heater or
the manufacturer listed on the rating plate for anode replacement
information. The use of a water softener may increase the speed of
anode consumption. More frequent inspection of the anode is needed
when using softened (or phosphate treated) water.
WARNING
When lifting lever of temperature-pressure relief valve, hot water will be
released under pressure. Be certain that any released water does not
result in bodily injury or property damage.
WARNING! THIS WATER MAY BE HOT.