Submittal

Standard Equipment
PI Controller
Outdoor reset with ratios of 0.4 to 3.6
Warm Weather Shutdown (WWSD)
Domestic Hot Water Operation (DHW)
Indicator lights for power, heat call,
DHW call and WWSD
Automatic boiler differential
Pump pre-purge, post-purge and
excercise
Codes for sensor errors
Venting: built-in draft diverter
• Designcertied/testedbyCSA
International
Natural or propane gas
Maximum working pressure:
water 30 P.S.I., ASME rated
Hydrostatictestpressureatfactory:60P.S.I.
Hydronic
Boilers
JVS Residential Gas-Fired Boiler
Indoor Sizes 50-225 MBTU/h
Submittal Data
Minimum Clearances, inches cm
Size Left + Right Sides, Rear Front Flue Top
50 6 15 4 10 6 15 23 58
75 6 15 4 10 6 15 23 58
100 6 15 4 10 6 15 23 58
125 6 15 4 10 6 15 23 58
160 6 15 4 10 6 15 36 91
225 6 15 4 10 6 15 36 91
• 30 psi ASME pressure relief valve
• Maximumgassupplypressure:Natural
10.5" W.C.; Propane 13" W.C.
• Pressurereliefvalve:capacityinex-
cess of boiler input rating
• MaterialspecicationsperSectionIV,
ASME Code
Headers: cast iron per ASME require-
ments
Tubes: copper with integral formed
externalns
Main burners: aluminized steel
• Airsupply:naturalaspiration
Altitudes: 0–10,000 ft.
Spark to pilot ignition
Electrical: 115V-60Hz-1PH less than 12
Amps 24V transformer mounted and
wired
Minimum
Clearances
from
Adjacent
Construction
MINI-THERM
®
JVS
• Pumprelay:standard
Vent damper and wire harness
• Blockedventsafetyswitch(B.V.S.S.)
• Flamerolloutsafetyswitch
Up to 85% AFUE
• 20-YearLimitedWarranty
Hydronic
Boilers
BJVS Residential Gas-Fired Boiler
Indoor Sizes 50-225 MBTU/h
BRUTE
MINI
Submittal Data
BJVS