The 14 updated pages of document 1295A. The Brute LX (Series 1, wall only) Installation and Operating Manual.
Page 41
Brute LX
Make adjustments in
1/16 of a revolution
increments until the
CO
2
is within range.
GAS TYPE
CO
2
(%) RANGE
)
Natural 8.9
__
9.9
Propane 9.9
__
10.9
Table 18. CO2 Range and Pressure Settings.
Figure 25. Adjustment Screws and Settings for CO
2
(Wall Mounted Brute LX)
Manifold
Pressure
Screw
(under cap)
Adjustment Screws on
Gas Valve.
Close door rst, before
measuring CO
2
Range
High-re
Adjustment
(2.5 mm Hex)
+
+
Low-re
Adjustment
(4 mm Hex)
(under slotted cap)
Note: High and Low Fire CO
2
settings
should be approximately equal.