Installation / Operation Instruction Manual
Table Of Contents
- Brute MagnaTech
- Table of Contents. Page 1
- SECTION 1 General Information
- SECTION 2 Venting and Combustion Air
- SECTION 3 Gas supply and Piping
- SECTION 4 Water Flow and Headloss Data
- SECTION 5 Piping
- SECTION 6 Condensate Drain Trap
- SECTION 7 Electrical Connections
- SECTION 8 Control Operation
- 8.A The Home Screen
- 8.B Login to Lock / Unlock the Display Screen
- 8.C Quick Start
- 8.D Configuration
- 8.E Service Screens
- 8.F Messages and USB
- 8.G Active Demands
- SECTION 9 Parameter Tables
- SECTION 10 Initial startup Instructions
- SECTION 11 Maintenance
- SECTION 12 Troubleshooting
- SECTION 13 Replacement Parts
- 13.A General Information
- 13.B Component Illustrations, Parts Lists, and Part Numbers
- 13.B.1 Final Assembly, Part Numbers
- 13.B.2 Frame and Jacket Assembly, Part Numbers
- 13.B.3 Control Panel, Part Numbers
- 13.B.4 Air / Gas System, Part Numbers (Model 1600)
- 13.B.5 Air / Gas System, Part Numbers (Model 2000)
- 13.B.6 Air / Gas System, Part Numbers (Models 2500 & 3000)
- 13.B.7 Air / Gas System, Part Numbers(Models 3500 and 4000)
- 13.B.8 AC Distribution Box, Part Numbers (Model 1600)
- 13.B.9 AC Distribution Box, Part Numbers (Model 2000)
- 13.B.10 AC Distribution Box, Part Numbers (Models 2500 to 4000)
- 13.B.11 Inlet Waterway Assemblies, Part Numbers
- 13.B.12 Outlet Waterway Assemblies, Part Numbers
- 13.B.13 Gas Train Assembly, Part Numbers(Models 1600, 2000, 2500 and 3000)
- 13.B.14 Gas Train Assembly, Part Numbers (Models 3500 and 4000)
Page 97
8.F.2 USB Functionality
Figure 44. Photo of USB Slot on
the back of touchscreen
display.
When the USB icon has appeared over the Message icon, press the USB
icon to access the USB menu. The following three tasks will be available:
• Download Parameters from the boiler: During a cascade setup or
a control replacement, enter the values in one unit, to copy into the
others.
• Upload Parameters from the boiler: Uploads all parameters and
settings into a thumb drive for documentation purposes, or copies these
settings from unit to unit.
•
Upload Data from the boiler: This is used to retrieve runtime data, and
history. It captures all settings in a tab delimited text le, for use with
spreadsheet programs.
8.F Messages and USB
8.F.1 Messages
The ‘Messages’ icon at the bottom of the home screen
displays an ‘Exclamation Point’ when messages are present.
Press the icon to see the message(s).
The USB port is on the back of the display. To access it, open
both panels and look for the black USB cable extending from the
back of the display. See Figure 44.