Installation / Operation Instruction Manual
Table Of Contents
- Brute MagnaTech
- Table of Contents. Page 1
- SECTION 1 General Information
- SECTION 2 Venting and Combustion Air
- SECTION 3 Gas supply and Piping
- SECTION 4 Water Flow and Headloss Data
- SECTION 5 Piping
- SECTION 6 Condensate Drain Trap
- SECTION 7 Electrical Connections
- SECTION 8 Control Operation
- 8.A The Home Screen
- 8.B Login to Lock / Unlock the Display Screen
- 8.C Quick Start
- 8.D Configuration
- 8.E Service Screens
- 8.F Messages and USB
- 8.G Active Demands
- SECTION 9 Parameter Tables
- SECTION 10 Initial startup Instructions
- SECTION 11 Maintenance
- SECTION 12 Troubleshooting
- SECTION 13 Replacement Parts
- 13.A General Information
- 13.B Component Illustrations, Parts Lists, and Part Numbers
- 13.B.1 Final Assembly, Part Numbers
- 13.B.2 Frame and Jacket Assembly, Part Numbers
- 13.B.3 Control Panel, Part Numbers
- 13.B.4 Air / Gas System, Part Numbers (Model 1600)
- 13.B.5 Air / Gas System, Part Numbers (Model 2000)
- 13.B.6 Air / Gas System, Part Numbers (Models 2500 & 3000)
- 13.B.7 Air / Gas System, Part Numbers(Models 3500 and 4000)
- 13.B.8 AC Distribution Box, Part Numbers (Model 1600)
- 13.B.9 AC Distribution Box, Part Numbers (Model 2000)
- 13.B.10 AC Distribution Box, Part Numbers (Models 2500 to 4000)
- 13.B.11 Inlet Waterway Assemblies, Part Numbers
- 13.B.12 Outlet Waterway Assemblies, Part Numbers
- 13.B.13 Gas Train Assembly, Part Numbers(Models 1600, 2000, 2500 and 3000)
- 13.B.14 Gas Train Assembly, Part Numbers (Models 3500 and 4000)
Page 9
E
U
B
A
VIEW
REAR
VIEW
REAR
N
Q
S
P
R
G
H
J
T
FRONT
VIEW
SIDE
VIEW
FRONT
VIEW
SIDE
VIEW
C
D
K
‘Knock-
down’
Height
Condensate Trap
1” Drain Hose on ALL Sizes
Contact
Factory
Op�onal
Flanges,
Vent
2” Gas ALL Sizes
Touchscreen
Display
Air Inlet
Pressure
Relief
Valve
Water
Outlet
Electrical
Connec�ons
Water
Inlet
E
U
B
A
VIEW
REAR
VIEW
REAR
N
Q
S
P
R
G
H
J
T
FRONT
VIEW
SIDE
VIEW
FRONT
VIEW
SIDE
VIEW
C
D
K
‘Knock-
down’
Height
Condensate Trap
1” Drain Hose on ALL Sizes
Contact
Factory
Op�onal
Flanges,
Vent
2” Gas ALL Sizes
Touchscreen
Display
Air Inlet
Pressure
Relief
Valve
Water
Outlet
Electrical
Connec�ons
Water
Inlet
Figure 1. Dimensions
E
F
U
B
A
VIEW
REAR
N
Q
S
P
M
R
L
G
H
K
J
T
FRONT
VIEW
SIDE
VIEW
C
D
Condensate Trap
Contact
Factory
Op�onal
Flanges,
Vent
Gas
6”x3.5”
Touchscreen
Display
Air Inlet
Pressure
Relief
Valve
Water
Outlet
‘Knock-
down’
Height
Water
Inlet
H
J
Gas
Air
Inlet
Model 4000
G
K
VIEWREAR
Models 3500 and 4000 dier from
the other sizes in the location of
their Air Inlet and Gas Supply.
Models 3500 / 4000