Installation / Operation Instruction Manual
Table Of Contents
- Brute MagnaTech
- Table of Contents. Page 1
- SECTION 1 General Information
- SECTION 2 Venting and Combustion Air
- SECTION 3 Gas supply and Piping
- SECTION 4 Water Flow and Headloss Data
- SECTION 5 Piping
- SECTION 6 Condensate Drain Trap
- SECTION 7 Electrical Connections
- SECTION 8 Control Operation
- 8.A The Home Screen
- 8.B Login to Lock / Unlock the Display Screen
- 8.C Quick Start
- 8.D Configuration
- 8.E Service Screens
- 8.F Messages and USB
- 8.G Active Demands
- SECTION 9 Parameter Tables
- SECTION 10 Initial startup Instructions
- SECTION 11 Maintenance
- SECTION 12 Troubleshooting
- SECTION 13 Replacement Parts
- 13.A General Information
- 13.B Component Illustrations, Parts Lists, and Part Numbers
- 13.B.1 Final Assembly, Part Numbers
- 13.B.2 Frame and Jacket Assembly, Part Numbers
- 13.B.3 Control Panel, Part Numbers
- 13.B.4 Air / Gas System, Part Numbers (Model 1600)
- 13.B.5 Air / Gas System, Part Numbers (Model 2000)
- 13.B.6 Air / Gas System, Part Numbers (Models 2500 & 3000)
- 13.B.7 Air / Gas System, Part Numbers(Models 3500 and 4000)
- 13.B.8 AC Distribution Box, Part Numbers (Model 1600)
- 13.B.9 AC Distribution Box, Part Numbers (Model 2000)
- 13.B.10 AC Distribution Box, Part Numbers (Models 2500 to 4000)
- 13.B.11 Inlet Waterway Assemblies, Part Numbers
- 13.B.12 Outlet Waterway Assemblies, Part Numbers
- 13.B.13 Gas Train Assembly, Part Numbers(Models 1600, 2000, 2500 and 3000)
- 13.B.14 Gas Train Assembly, Part Numbers (Models 3500 and 4000)
Page 1
This manual includes information which will help you to
install, operate, and maintain the Bradford White Brute
MagnaTech high eciency commercial boiler or volume
water heater. Please read this manual completely
before proceeding with the installation. If you have any
questions regarding this equipment, please consult the
manufacturer or your local manufaturers representative
via the website listed on the back cover of this manual.
Experience has shown that most operating problems
are caused by improper installation.
Bradford White Brute MagnaTech boilers and volume
water heaters are covered by a limited warranty. The
owner should complete the warranty registration at
http://www.BradfordWhite.com
ALL WARRANTY CLAIMS must be made by an
authorized Bradford White representative. Claims must
include the serial number and model (this information
can be found on the rating plate). All claims must also
include the installation date and name of the installer.
Shipping costs are not included in the warranty
coverage.
SECTION 1 General Information
Rating Plate
1.A Introduction
1.B ModelIdentication
Primary information regarding your unit can be found
on the Rating Plate on the outside face of the
right-side panel.
1.C Warranty
1 2 3 4 5 6 7 8 9 10 11 12 13
M G 3
M G 1 6 0 0
2 0 0 0
2 5 0 0
3 0 0 0
3 5 0 0
4 0 0 0
X- std MGH, 75psi PRV, H-Stamp N- MGV w/ H-Stamp, 30psi PRV
W- std MGV, 125psi PRV, HLW-Stamp P- MGV w/ H-Stamp, 50psi PRV X- None H- Gateway LONworks
A- 30psi PRV R- MGV w/ H-Stamp, 60psi PRV A- Gateway, BACnet IP* & alarm bell
B- 50psi PRV S- MGV w/ H-Stamp, 75psi PRV B- Gateway, LONworks J- Gateway LONworks
C- 60psi PRV T- MGV w/ H-Stamp, 125psi PRV C- Alarm bell & high limits
D- MGV 75psi PRV U- MGV w/ H-Stamp, 150psi PRV D-
Auto & manual
K- Gateway LONworks
E- MGH 125psi PRV 2- Flange kit, MGV w/ H-Stamp, 30psi PRV high limits & alarm bell
F- 150psi PRV
3- Flange kit, MGV w/ H-Stamp, 50psi PRV E- Gateway BACnet IP* & high limits
G- Flange kit & 30psi PRV
4- Flange kit, MGV w/ H-Stamp, 60psi PRV & alarm bell L- Alarm & high limits
H- Flange kit & 50psi PRV
5- Flange kit, MGV w/ H-Stamp, 75psi PRV F- Gateway BACnet IP*
J- Flange kit & 60psi PRV 6- Flange kit, MGV w/ H-Stamp, 125psi PRV & high limits *BACnet Gateway is
K- Flange kit & 75psi PRV 7- Flange kit, MGV w/ H-Stamp, 150psi PRV G- Gateway BACnet IP* used for BACnet IP
L- Flange kit & 125psi PRV & alarm bell and Modbus TCP/ IP
M- Flange kit & 150psi PRV & high limits
Additional Options
Waterway Options
D- 480V, three ph (2000-4000)
E- 600V, three ph (2000-4000)
C- 208V, three ph (2000-4000)
B- 220/240V, single ph (1600-2000)
F- 208V, single ph (1600-2000)
A- 120V, single ph (1600-2000)
Electrical System
3- Third
Revision
Model Nomenclature
Series
Size / MBH
J- CSD-1
X- Standard
Construction
P- LP
N- Nat
Fuel
V - Volume Water
Usage
H - Hydronic
1 2 3 4 5 6 7 8 9 10 11 12 13
M G 3
M G 1 6 0 0
2 0 0 0
2 5 0 0
3 0 0 0
3 5 0 0
4 0 0 0
X- std MGH, 75psi PRV, H-Stamp N- MGV w/ H-Stamp, 30psi PRV
W- std MGV, 125psi PRV, HLW-Stamp P- MGV w/ H-Stamp, 50psi PRV X- None H- Gateway LONworks
A- 30psi PRV R- MGV w/ H-Stamp, 60psi PRV A- Gateway, BACnet IP* & alarm bell
B- 50psi PRV S- MGV w/ H-Stamp, 75psi PRV B- Gateway, LONworks J- Gateway LONworks
C- 60psi PRV T- MGV w/ H-Stamp, 125psi PRV C- Alarm bell & high limits
D- MGV 75psi PRV U- MGV w/ H-Stamp, 150psi PRV D-
Auto & manual
K- Gateway LONworks
E- MGH 125psi PRV 2- Flange kit, MGV w/ H-Stamp, 30psi PRV high limits & alarm bell
F- 150psi PRV
3- Flange kit, MGV w/ H-Stamp, 50psi PRV E- Gateway BACnet IP* & high limits
G- Flange kit & 30psi PRV
4- Flange kit, MGV w/ H-Stamp, 60psi PRV & alarm bell L- Alarm & high limits
H- Flange kit & 50psi PRV
5- Flange kit, MGV w/ H-Stamp, 75psi PRV F- Gateway BACnet IP*
J- Flange kit & 60psi PRV 6- Flange kit, MGV w/ H-Stamp, 125psi PRV & high limits *BACnet Gateway is
K- Flange kit & 75psi PRV 7- Flange kit, MGV w/ H-Stamp, 150psi PRV G- Gateway BACnet IP* used for BACnet IP
L- Flange kit & 125psi PRV & alarm bell and Modbus TCP/ IP
M- Flange kit & 150psi PRV & high limits
Additional Options
Waterway Options
D- 480V, three ph (2000-4000)
E- 600V, three ph (2000-4000)
C- 208V, three ph (2000-4000)
B- 220/240V, single ph (1600-2000)
F- 208V, single ph (1600-2000)
A- 120V, single ph (1600-2000)
Electrical System
3- Third
Revision
Model Nomenclature
Series
Size / MBH
J- CSD-1
X- Standard
Construction
P- LP
N- Nat
Fuel
V - Volume Water
Usage
H - Hydronic
Brute
MagnaTech
Series
B M G
B M G
1 2 3 4 5 6 7 8 9 10 11 12 13 14