Installation / Operation Instruction Manual

Table Of Contents
Page 53
10
AMP
2
AMP
BKBK
BK BK
GGNNHHL2L1
A
B
C
CIRCUIT
BREAKER
L2L1
L1 L2
W
G
BK
CONVENIENCE
RECEPTACLE
GFCI
2 AMP
N
G
H
3
AMP
+
120V
--
+
24V
YW
BK BL
4 AMP
5
4
6
123
G
Y BL
W
BK/O
BK
L3L2L1
BLOWER
BK
R
R
BK
L2L1
CONTACTOR
A2A1
T2
T1
BK W
CONNECT TO
MAIN CTRL
PANEL
H2359100
TB1 45B
TB1 44B
BK
W
5
2
PE
41
0-10V
U/T1 V/T2 W/T3
NL1 L2
VFD
TO CONNECTOR "E"
ON DIAGRAM
E23512
BK
G
SP1000MGMJ
H4
H2
H3
H1
X4
X1
X3
X2
HV
220VAC
R
BL
R
BK
G
BK
R
GND
L2
BK
W
E23603
D
C
B
A
B
C
D
1
2
3
4
4
3
2
MAGNATHERM
FRACTIONS 1/8"
BY LAARS HEATING SYSTEMS.
FMA56A
DWG NO.
E23603
SH
1
REV
A
CH 2/17/16
REVISIONS
REV.
CHANGE:
APPR
ENGR APPR
ECN
DRAFT
CHECK
UPDATED VFD CONNECTIONS
A
16-017N AH 2/17/16
SCALE: NONE
INTENDED SIZE:
SOFTWARE
DWG. NO:
C
SHEET 1 OF 3
REV.
APPROVALS
DRAFT
ENGR
APPR
UNLESS OTHERWISE SPECIFIED:
PURPOSE EXCEPT AS SPECIFICALLY AUTHORIZED IN WRITING
DISCLOSED TO OTHERS FOR MANUFACTURING OR ANY OTHER
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
MATERIAL:
FINISH
NA
NA
JM 2-6-14
S
AL 2-6-14
DO NOT SCALE DRAWING.
THIRD ANGLE PROJECTION.
.1 DECIMALS .X
.03DECIMALS .XX
.010
REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, USED OR
PROPRIETARY TO LAARS HEATING SYSTEMS AND SHALL NOT BE
DECIMALS .XXX
TITLE:
1
THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN ARE
ANGLES
WIRING DIAGRAM, HIGH
VOLTAGE, 220V 1Ø,
A
WIRE COLOR LEGEND
BLACK BK
BROWN BR
RED R
ORANGE O
YELLOW Y
GREEN G
BLUE BL
VIOLET V
GRAY GY
WHITE W
Figure 29. High Voltage Wiring Diagram Model 2000, 220V / 240V Single Phase