Installation / Operation Instruction Manual
Table Of Contents
- Brute MagnaTech
- Table of Contents. Page 1
- SECTION 1 General Information
- SECTION 2 Venting and Combustion Air
- SECTION 3 Gas supply and Piping
- SECTION 4 Water Flow and Headloss Data
- SECTION 5 Piping
- SECTION 6 Condensate Drain Trap
- SECTION 7 Electrical Connections
- SECTION 8 Control Operation
- 8.A The Home Screen
- 8.B Login to Lock / Unlock the Display Screen
- 8.C Quick Start
- 8.D Configuration
- 8.E Service Screens
- 8.F Messages and USB
- 8.G Active Demands
- SECTION 9 Parameter Tables
- SECTION 10 Initial startup Instructions
- SECTION 11 Maintenance
- SECTION 12 Troubleshooting
- SECTION 13 Replacement Parts
- 13.A General Information
- 13.B Component Illustrations, Parts Lists, and Part Numbers
- 13.B.1 Final Assembly, Part Numbers
- 13.B.2 Frame and Jacket Assembly, Part Numbers
- 13.B.3 Control Panel, Part Numbers
- 13.B.4 Air / Gas System, Part Numbers (Model 1600)
- 13.B.5 Air / Gas System, Part Numbers (Model 2000)
- 13.B.6 Air / Gas System, Part Numbers (Models 2500 & 3000)
- 13.B.7 Air / Gas System, Part Numbers(Models 3500 and 4000)
- 13.B.8 AC Distribution Box, Part Numbers (Model 1600)
- 13.B.9 AC Distribution Box, Part Numbers (Model 2000)
- 13.B.10 AC Distribution Box, Part Numbers (Models 2500 to 4000)
- 13.B.11 Inlet Waterway Assemblies, Part Numbers
- 13.B.12 Outlet Waterway Assemblies, Part Numbers
- 13.B.13 Gas Train Assembly, Part Numbers(Models 1600, 2000, 2500 and 3000)
- 13.B.14 Gas Train Assembly, Part Numbers (Models 3500 and 4000)
Page 77
8.D.4.c Rotation
To navigate to the Cascade Rotation Screen, touch the Cascade Icon on the Congure Screen, then touch the
Rotation Icon on the Cascade Conguration Screen.
The Cascade Rotation Screen is a view
only screen. This screen indicates how many units are connected in
a cascade conguration, the order in which each unit will run, and the percent at which each unit is running.
8.D.4.c.1 Rotation Setup
The Rotation Setup button is found only on the boiler that is assigned as ‘Lead’.
For Recurrence Mode, there are two parameters:
1. Time of Day. You can adjust the hour and minute
of the day for rotation.
2. Every X Days. You can select how many days you
want to wait until rotation, and then it will rotate at
the hour and minute of the day previously selected.
There are two options for cascade Rotation Setup, Rotation ‘Mode’:
1. Run Time
2. Recurrence
The red circle with the exclamation mark means
that that boiler is locked out and will need to be
manually reset to return to operations.
The blue circle means that that boiler has a soft
or auto-reset condition and the lead boiler has
placed it later in the queue to attempt to re-re.
In the Run Time Mode, you can adjust only the
Rotation Run Time Hours. This chooses which
unit will re rst based on run time hours.
CONFIGURATION