Submittal

Clearances
* Whenventand/orcombustionairconnectstotheback,recommendedclearance
is 36" 91cm.
** 1"whenb-ventisused.
Required Clearance from Suggested Service
Appliance Combustible Material Access Clearance
Surface inches cm inches cm
Left Side 1 2.5 24 61.0
RightSide 1 2.5 24 61.0
Top 1 2.5 12 30.5
Back* 1 2.5 12 30.5
Front 1 2.5 36 91.4
Vertical Vent** (Category 1) 6 15.2
Horizontal Vent (Category 3) per UL1738 venting system supplier's instructions
Recovery
Data
WATER TEMPERATURE RISE IN °F
40°F 50°F 60°F 70°F 80°F 90°F 100°F 120°F 140°F
Size GPH GPH GPH GPH GPH GPH GPH GPH GPH
200 510 408 340 291 255 227 204 170 146
300 765 612 510 437 383 340 306 255 219
400 1020 816 680 583 510 453 408 340 291
NOTE: GPH = gallons per hour.
WATER TEMPERATURE RISE IN °C
22°C 28°C 33°C 39°C 44°C 50°C 56°C 67°C 78°C
Size L/h L/h L/h L/h L/h L/h L/h L/h L/h
200 1928 1542 1285 1100 964 858 771 643 552
300 2892 2313 1928 1652 1448 1285 1157 964 828
400 3856 3084 2570 2204 1928 1712 1542 1285 1100
NOTE: L/h = Liters per hour.
Pump Data
Water Category
Size SOFT NORMAL
HP Amps HP Amps
200 1/10 1.5 1/6 2.0
300 1/10 1.5 1/6 2.0
400 1/10 1.5 1/6 2.0
Size HP Amps
400 1/6 2.0
MT2H Boilers
MT2V Water Heaters
Electrical
Data
MT2H&MT2V Boiler/HeaterCircuitSize Pump Blower
(pump mounted)
Size Volts Phase Amps
Included
200–400 120 Single 15 Included in Boiler Connection in Boiler
Connection
BMT2HBMT2V
BMT2H&BMT2V