Submittal

Clearances
* Whenventand/orcombustionairconnectstotheback,recommendedclearance
is36"91cm.
** 1"whenb-ventisused.
Required Clearance from Suggested Service
Appliance Combustible Material Access Clearance
Surface inches cm inches cm
Left Side 1 2.5 24 61.0
RightSide 1 2.5 24 61.0
Top 1 2.5 12 30.5
Back* 1 2.5 12 30.5
Front 1 2.5 36 91.4
Vertical Vent**
(Category 1) 6 15.2
Horizontal Vent
(Category3) perUL1738ventingsystemsupplier'sinstructions
Recovery
Data
WATER TEMPERATURE RISE IN °F
40°F 50°F 60°F 70°F 80°F 90°F 100°F 120°F 140°F
Size GPH GPH GPH GPH GPH GPH GPH GPH GPH
200 510 408 340 291 255 227 204 170 146
300 765 612 510 437 383 340 306 255 219
400 1020 816 680 583 510 453 408 340 291
NOTE: GPH = gallons per hour.
WATER TEMPERATURE RISE IN °C
22°C 28°C 33°C 39°C 44°C 50°C 56°C 67°C 78°C
Size L/h L/h L/h L/h L/h L/h L/h L/h L/h
200 1928 1542 1285 1100 964 858 771 643 552
300 2892 2313 1928 1652 1448 1285 1157 964 828
400 3856 3084 2570 2204 1928 1712 1542 1285 1100
NOTE: L/h = Liters per hour.
Electrical
Data
MT2H&MT2V Boiler/HeaterCircuitSize PumpDelayConnectionRating Blower
(non-pump mounted)
Size Volts Phase Amps PilotDuty Phase Power
Included
200–400 120 Single 15 24V Single
Up to
in Boiler
25VA
Circuit
BMT2H & BMT2V