Spec Sheet

Residential Atmospheric Vent Combi2
®
Gas Water Heater System
10-Year Limited Tank and Heat Exchanger Warranties / 6-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
Photo is of
C-DW2-504T10FBN
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419;
7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925;
5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007;
2,092,105; 2,107,012. Combi2
®
, Defender Safety System
®
, Vitraglas
®
, Hydrojet
®
and ScreenLok
®
are registered trademarks of Bradford White
®
Corporation.
545-G-0122
The Combi2
®
FVIR Defender Safety System
®
Model Features (C-DW2-504T10FBN
model only):
n Advanced ScreenLok
®
Technology Flame Arrestor Design—Flame arrestor is
designed to prevent ignition of flammable vapor outside of the water heater.
n Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner
and pilot operation in case of ongoing flammable vapors burning inside of the
combustion chamber or restricted air flow.
n Maintenance Free—Regular cleaning of air inlet openings or flame arrestor is not
required under normal conditions.
n Sight Window—Offers a view into the combustion chamber to observe the
operation of the pilot and burner.
All Combi2
®
Models Feature:
n Bradford White ICON System
®
Intelligent gas control with proven millivolt
powered technology and built-in piezo igniter. A standard, off-the-shelf thermopile
converts heat energy from the pilot flame into electrical energy to operate the gas
valve and microprocessor. No need for external electricity.
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour
Rating and tighter temperature differential.
-- Advanced Temperature Control System—Microprocessor controls burner
operation for consistent and accurate water temperature levels up to 180°F
(82°C).
-- Intelligent Diagnostics—Exclusive multicolor LED light indicates operation
status/service required.
n Internal Double Wall Heat Exchanger—Double wall 1
1
2" (38mm) O.D. glass coated
(Vitraglas
®
) steel coil ensures separation of potable water and heating fluid.
-- 3/4" (19mm) NPT Front Supply and Return Connections.
-- Low Heat Exchanger Head Loss—Up to 8 GPM (30 LPM) flow, with less than 6
ft. (1.8m) of head loss. Greatly reduces the required pump size for heat exchange.
n Factory Installed Hydrojet
®
Total Performance System—ediment reducing device
that also increases first hour rating of hot water while minimizing temperature build-up
in tank.
n Vitraglas
®
Lining—An exclusively engineered enamel formula that provides superior
tank protection from the highly corrosive effects of hot water. This formula (Vitraglas
®
)
is fused to the steel surface by firing at a temperature of over 1600°F (871°C).
n Insulation System—2" (51mm) Non-CFC foam insulation covers the sides and top
of the tank, reducing heat loss. This results in less energy consumption, improved
efficiencies, and jacket rigidity.
n Pedestal Base.
n Water Connections—3⁄4" (19mm) NPT factory installed true dielectric fittings.
n Two Protective Anode Rods.
n T&P Relief Valve—Installed.
n Low Restrictive Brass Drain Valve—Durable tamper proof design.
n Thermostatic Mixing Valve (ASSE Approved)—Included.
FEATURING:

Summary of content (2 pages)