Installation / Operation Instruction Manual
Table Of Contents
- WITH TROUBLESHOOTING GUIDE
- Non-Flue Damper Models (Figure 2)
- Flue Damper Models and Non-Flue Damper Models (Figure 3)
- Non-Flue Damper Models (Figure 4)
- Front, sides and Rear “A”
- Input
- 2 in. (5.1 CM)
- Less than or equal to 300,000 BTUH
- 6 in (15.2 CM)
- Greater than 300,000 BTUH
- IMPORTANT-The flow of combustion and ventilating air must not be obstructed.
- MECHANICAL EXHAUSTING OF ROOM AIR - Where an exhaust fan is installed in the same room with this water heater and combustion air is drawn from inside the room, sufficient openings for air must be provided in the walls. UNDERSIZED OPENINGS WILL CAUSE A...
2
SECTION I: IMPORTANT INFORMATION
This w ater heater has a limited w arranty. The w arranty for this w ater heater is valid only if the w ater heater
has been installed, maintained and operated in accordance with these instructions. The warranty does not
cover damage or injury caused by the use of any energy-saving devices (other than those authorized by the
manufacturer) in conjunction with this water heater. The use of unauthorized energy-saving devices may
decrease the life of the water heater and endanger life and/or property. The manufacturer will not be liable for
any damage, injury, or loss of life resulting from alteration and/or failure to comply with these instructions.
IMPORTANT-Before proceeding, please inspect the water heater and components for possible damage. DO NOT
install damaged components. If damage is evident, please contact the supplier where the water heater was
purchased or the manufacturer listed on the rating plate for replacement parts.
NOTICE
I
IMPORTANT INFORMATION..........................2
VIII
ELECTRICAL CONNECTIONS.....................21
II
SPECIFICATIONS............................................5
IX
OPERATING INSTRUCTIONS......................23
III
GENERAL INFORMATION..............................8
X
MAINTENANCE.............................................32
IV INSTALLATION INSTRUCTIONS..................10 XI
DIAGNOSTIC AND TROUBLESHOOTING
GUIDE............................................................34
V
VENTING........................................................15
XII
PARTS LIST...................................................54
VI WATER CONNECTIONS……………………..17 XIII
INSTALLATION FOR POTABLE
WATER AND SPACE HEATING...................55
VII
GAS CONNECTIONS....................................19
XIV
NOTES………………………………………….56
TABLE OF CONTENTS
This gas-fired water heater is design certified by CSA International under the American National Standard,
Z21.10.3 and CAN/CGA 4.3-M (as indicated on the rating plate). These standards are available from CSA
Standards Association, 5060 Spectrum Way Mississauga, Ontario L4W 5N6 CANADA.
This water heater must be installed in accordance with local codes. In the absence of local codes, it must be
installed in compliance with the National Fuel Gas Code (ANSI Z223.1-Latest Edition), or in Canada CAN/CGA
B149.1 Natural Gas Installation Code (Latest Edition) or CAN/CGA B149.2 Propane Installation Code (Latest
Edition).
The following terms are used throughout this manual to bring attention to the presence of hazards at various
risk levels, or to important information concerning product life.
READ CAREFULLY
Indicates special instructions on installation,
operation or maintenance, which are important
but not related to personal injury hazards.
NOTICE
Indicates a potentially hazardous situation, which,
if not avoided, could result in death, serious injury
or substantial property damage.
WARNING
Indicates potentially hazardous situation, which, if
not avoided, may result in moderate or minor
injury or property damage.
CAUTION
Indicates an imminently hazardous situation,
which, if not avoided, will result in death, serious
injury or substantial property damage.
DANGER