SECTION II: SPECIFICATIONS
Non-Flue Damper Models and Flue Damper Models (Figure 1)
Model Description
A
(in)
B
(in)
C
(in)
D
(in)
E
(in)
F
(in)
Capacity
(GAL)
Input (BTU/hr)
Nat.
LP
100
199,999
199,999
75.00
64.75
56.50
4.63
23
6
100
250,000
250,000
75.00
64.75
56.50
4.63
23
6
100
270,000
N/A
75.00
64.75
56.50
4.63
23
6
100
300,000
300,000
75.44
64.75
56.50
4.63
23
7
80
399,999
375,000
71.50
60.25
51.50
10.25
N/A
8
80
450,000
425,000
69.00
60.25
51.50
10.25
N/A
10
80
505,000
475,000
69.00
60.25
51.50
10.25
N/A
10
Model Description
A
(cm)
B
(cm)
C
(cm)
D
(cm)
E
(cm)
F
(cm)
Capacity
Input (kW/hr)
(Litres)
Nat.
LP
378.5
58.6
58.6
191
164
144
11.8
58.4
15.2
378.5
73.2
73.2
191
164
144
11.8
58.4
15.2
378.5
79.1
N/A
191
164
144
11.8
58.4
15.2
378.5
87.9
87.9
192
166
144
11.8
58.4
17.8
302.8
117.2
109.9
181
153
131
26.0
N/A
20.3
302.8
131.8
124.5
175
153
131
26.0
N/A
25.4
302.8
148.0
139.2
175
153
131
26.0
N/A
25.4
1. N/A - Denotes not available.
Non-Flue Damper Models (Figure 2)
Model Description
A
(in.)
B
(in.)
C
(in.)
D
(in.)
Capacity
(GAL)
Input
(BTU/hr)
65
370,000
71.38
64.75
54.13
8
65
399,999
(NAT ONLY)
71.38 64.75 54.13 8
75
300,000
72.00
65.75
54.13
7
80
425,000
81.00
75.50
64.50
10
80
505,000
81.00
75.50
64.50
10
Model Description
A
(cm)
B
(cm)
C
(cm)
D
(cm)
Capacity
(Litres)
Input
(kW/hr)
246.1
108.4
181
164
137
20.3
246.1
117.2
(NAT ONLY)
181 164 137 20.3
283.9
87.9
183
167
137
17.8
302.8
124.5
206
192
164
25.4
302.8
148.0
206
192
164
25.4
Flue Damper Models (Figure 2)
Model Description
A
(in.)
B
(in.)
C
(in.)
D
(in.)
Capacity
(GAL)
Input
(BTU/hr)
65
370,000
73.25
64.75
54.50
8
65
399,999
(NAT ONLY)
73.25 64.75 54.50 8
75
300,000
75.88
65.75
54.13
7
80
425,000
82.75
75.50
64.50
10
80
505,000
82.75
75.50
64.50
10
Model Description
A
(cm)
B
(cm)
C
(cm)
D
(cm)
Capacity
(Litres)
Input
(kW/hr)
246.1
108.4
186
165
138
20.3
246.1
117.2
(NAT ONLY)
186 165 138 20.3
283.9
87.9
193
167
138
17.8
302.8
124.5
210
192
164
25.4
302.8
148.0
210
192
164
25.4
Figure 1