Service Manual

73
Sensor shown fully
inserted into well
Sensor clip shown
installed properly
Service Procedure I
Thermostat Circuit Testing and Replacement (Continued)
Thermostat Sensor (Thermister)
Replacement Procedure
1. Position main power switch to OFF.
2. Disconnect (unplug) the water heater from 120
volt power source.
3. Unlatch and remove the top of the surround
cover from the top of the water heater.
4. Fold back the insulation just in front of the
burner to expose the temperature sensor (see
image at right).
5. Disconnect temperature sensor from harness
(see images at right).
6. Unclip the sensor from the well and pull the
sensor to remove, do NOT remove the well.
NOTE: Using a deep well socket will allow
room inside socket for sensor connector
and wires.
7. Install the new sensor completely into the well
and reinstall the sensor clip.
8. Fold the insulation back into place. Be sure
there are no wires in contact with the burner.
9. Restore 120 volt power supply and water supply
to the water heater, check and repair any leaks
found. Confirm proper operation following the
lighting instruction label or the lighting
instruction located in the Installation and
Operating Instruction Manual.
10. Replace the surround cover on the top of the
water heater.
WARNING
120 volt potential exposure. Isolate the appliance and
reconfirm power is disconnected using a multi-meter.
Insulation folded
back to expose
temperature sensor
73