Service Manual

84
With ohmmeter check
pressure switch for continuity.
Contacts should be closed.
Is pressure in exhaust tube near 2.7" W.C. or more? If so, correct
blockage (above). If exhaust pressure is low (0.40" or less),
replace pressure switch.
Pressure switch O.K.
Service Procedure VI
Blocked Vent Pressure Switch Testing and Replacement (Continued)
Check Exhaust Tube Pressure
With manometer, take a
reading at the exhaust tube pressure
tap location. Is value negative (-) or
slightly positive (see image below).
Is exhaust venting system
blocked or obstructed? Check
condensate elbow and drain.
Clear obstruction.
Determine cause
and correct.
Is vent system total length
compliant with vent tables in
the instruction manual?
Replace blocked vent switch (see
Blocked Vent Switch Testing and
Replacement, pg 85).
Reconfigure vent system
to be compliant with vent
tables (see
Specifications, pg 53).
N
N
N
N
Y
Y
Y
Y
84