Installation / Operation Instruction Manual
3 238‐50320‐00B 9/15
InstallPVCpipecouplingoverairintakepipeconnection
andcementtopipeusingappropriatesolventandcement. WetgasketsofDuraVentPVCAdapterusingfinger.
InsertmalegasketedendofDuraVent
PVCadapterintoPVCpipecoupling. InstallDuraVentAdapterConnector Clamp(PPS‐PAC)overthe
PVCcoupling sothatclampbracketssecuretheshoulderofPVC
adapterfitting. Tightenclampscrewssecurely.
PVCPipeCoupling(not
suppliedwithwaterheater)
WaterHeaterPVCAirIntake
Pipe.Useappropriate
solventandcementto
cementcouplingtopipe.
Wetgasket usingwater
withfinger
MaleGasketedendofPVC
adapter
FlueClampbandfitoverPVCAdapter
shoulderandPVCCoupling.Tighten
clampscrewssecurelywithscrewdriver.
WARNING
DuraVent Adapter Connector Clamps (p/n: PPS-PAC) MUST be properly
installed to secure the PVC Vent Adapter. DO NOT operate the vent system
without first installing the Flue Adapter Connector Clamps.