Installation / Operation Instruction Manual

7 2385032000B 9/15
Step4:Usingafingerorpapertowel,wetwithwatertheinsidegasketofthePVCadapterandthemaleend(without
gasket)oftheelboworstraightsectionofpipeforrunningtheexhaustorintakepipefromthewaterheater.
SteeljointLockingBands(availablefromDuraVentsupplier)mustbeusedateachpipejoint. Theconnectorringsensure
thatthejointsdonotseparateunderheavyloads. Theseconnector
ringsmustbeusedtocomplywithULCS636
requirements.Seefollowingphotowiththejointconnectorattachedtothepipesections.
InsertaLockingBandoverthemaleendoftheventpip esectionwiththehookandlegfacingthejoint. Insertthemale
endoftheelbowor
straightsectionintothePVCadapter. Useatwistingmotionwhilepushingthemaleend ofthepipe
orelbowintothePVCadaptertofullyseatintothegasket. Themaleendofthepipeorelbowmustalwayspointtoward
thewaterheater.
SecureLockingBandtoconnectionjointbyslidingthehookoverthelipofthejointasshownbelow.

Useatwistingmotiontoinsertmaleendof
ventpipesectionintoPVCAdapter
LockingBand first inserted over end of
vent pipe section
PushhookofLockingBandoverthelipof
thejointtosecuretheventpipe
PVCAdapter
WARNING
DO NOT operate vent system without
properly installing Locking Bands.